2.1 Overview
2-3
2
Pane
l Ope
rato
r
2.1.3
Status Display
The display shows the following status.
Bit Data
Code
Analog
Code
Meaning
Code
Meaning
Baseblock
Servo OFF (servomotor power OFF)
Reverse Run Prohibited
N-OT is OFF.
Run
Servo ON (servomotor power ON)
Safety Function
The SERVOPACK and converter are
baseblocked by the safety function.
Forward Run Prohibited
P-OT is OFF.
Alarm
Flashes the alarm number.
Display
Meaning
Control Power ON
Lit while the control power supply to the multi-winding drive unit is ON.
Not lit while the control power supply to the multi-winding drive unit is OFF.
Baseblock
Lights when the servomotor is OFF.
In speed control: Speed Coincidence (/V-CMP)
Lights when the difference between the servomotor speed and reference speed is the same as or less than the
value set in Pn503. (Factory setting: 10 min
-1
)
∗
Always lights in torque control.
Note: If there is noise in the reference voltage during speed control, the horizontal line (-) at the far left edge
of the panel operator display may flash. Refer to
3.11.1 Wiring for Noise Control
and take a preventive
measures.
In position control: Positioning Completion (/COIN)
Lights if error between position reference and actual motor position is less than the value set in Pn522. (Fac-
tory setting: 7 reference units)
Rotation Detection (/TGON)
Lights if motor speed exceeds the value set in Pn502. (Factory setting: 20 min
-1
)
In speed control: Speed Reference Input
Lights if input speed reference exceeds the value set in Pn502. (Factory setting: 20 min
-1
)
In position control: Reference Pulse Input
Lights if reference pulse is input.
In torque control: Torque Reference Input
Lights if input torque reference exceeds preset value (10% of the rated torque).
In position control: Clear Signal Input
Lights when clear signal is input.
Power Ready
Lights when main circuit power supply is ON.