3.1 Main Circuit Wiring
3-5
3
Wirin
g and
Co
nnectio
n
Converter
CN101
CN103,
CN104
P, N
L1, L2, L3
B1, B2
1,
ࠉ
2
Converter
SGDV-COA5EDA
Connectors/
Terminals
Name
Specifications
L1, L2, L3
Main circuit power input terminals
Three-phase, 380 to 480 VAC, +10% to -15%, 50/60 Hz
CN101
Control power input connector
24 VDC,
±
15%
Mating connector model: 231-202/026-000 (Manufactured by
Wago Company of Japan, Ltd)
P, N
Main circuit DC voltage output ter-
minals
Connect these terminals to the P and N terminals on the SERVO-
PACK.
Ground terminal
Connect this terminal to the power supply ground terminal and
then ground it.
B1, B2
Regenerative resistor connection
terminals
Connect these terminals to the regenerative resistor unit.
1, 2
DC reactor connection terminals
Remove the short bar before you connect a DC reactor.
CN103,
CN104
Control power output connectors
CN103 and CN104 output 24 VDC to the SERVOPACK.
The 24-VDC (±15%) input is output unaltered from CN103.
CN104 provides the same output, but it is normally not neces-
sary to connect it.
Pin 2: 24 V
Pin 1: 0 V