3.6 Wiring MECHATROLINK-
II
Communications
3-27
3
Wirin
g and
Co
nnectio
n
3.6
Wiring MECHATROLINK-
II
Communications
The following diagram shows an example of connections for MECHATROLINK-II communications between
a host controller and a multi-winding drive unit.
The MECHATROLINK-II communications cable connectors (CN9A and CN9B) are used.
Note 1. The length of the cable between stations (L1, L2 ... Ln) must be 0.5 m or more.
2. The total cable length must be L1 + L2 ... + Ln
≤
50.
3. When multiple multi-winding drive units or SERVOPACKs are connected by MECHATROLINK-II communica-
tions cables, a terminator must be installed at the final multi-winding drive unit or SERVOPACK.
Terminator
Option
Option
Ln
L1
L2
DC24V
DC 0V
MP2300
YASKAWA
TEST
ࠉ
ࠉ
ࠉ
RDY
ALM
TX
RUN
ERR
BAT
MON
CNFG
INT
SUP
STOP
SW1
OFF
ON
BATTERY
CPU I/O
M-
I
/
II
218IF-01
ERR
COL
RX
RUN
STRX
TX
INIT
TEST
ON
OFF
PORT