5.2 Basic Functions Settings
5-19
5
Ope
rat
ion
(2) Related Parameters
∗
The setting unit is a percentage of the rated torque.
Note: When using SEMI F47 function, set 1000 ms.
Parameter
Meaning
When Enabled Classification
Pn008
n.
0
[Factory setting]
Does not detect undervoltage.
After restart
Setup
n.
1
Detects warning and limits torque by host controller.
n.
2
Detects warning and limits torque by Pn424 and Pn425.
(Only in the SERVOPACK)
Pn424
Torque Limit at Main Circuit Voltage Drop
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 100
1%
*
50
Immediately
Setup
Pn425
Release Time for Torque Limit at Main Circuit
Voltage Drop
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0 to 1000
1 ms
100
Immediately
Setup
Pn509
Instantaneous Power Cut Hold Time
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
20 to 50000
1 ms
20
Immediately
Setup
Speed
Position
Torque
Speed
Position
Torque
Speed
Position
Torque