3 Wiring and Connection
3.1.2 Main Circuit Wire
3-6
(2) Wire Sizes
The following table shows the symbols for the power input terminals, screw sizes for terminals, tightening
torque, wire sizes, and crimp terminals used for the SERVOPACKs and converters.
For Three-phase, 200V
∗1.
Use SERVOPACKs and converters in the specified combinations.
∗2.
Use the crimp terminals that are recommended by Yaskawa or an equivalent.
Combination of SERVO-
PACK and Converter
*1
Terminal
Symbols
Screw Size
for Terminals
Tightening
Torque
(N m)
HIV Wire Size in
mm
2
(AWG)
Crimp Terminal
Model
(Made by J.S.T.
Mfg Co., Ltd.)
*2
SGDV-121H
SGDV-
COA2BAA
SERVO-
PACK
P, N
M8
15.0
Bus bar attached
to the converter
–
U, V, W
M8
3.0
60 (2/0)
R60-8
DU, DV, DW
M6
3.0
5.5 (10)
R5.5-6
M8
9.0 to 1.0
60 (2/0)
R60-8
Converter
P, N
M8
3.0
Bus bar attached
to the converter
–
L1, L2, L3
M8
3.0
38 (1)
R38-8
1, 2
M8
3.0 38
(1)
R38-8
CN101
(L1C, L2C)
–
(Connector)
–
1.25 (16)
–
B1, B2
M8
3.0
8 (8)
R8-8
M8
9.0 to 11.0
38 (1)
R38-8
SGDV-161H
SGDV-
COA3GAA
SERVO-
PACK
P, N
M8
15.0
Bus bar attached
to the converter
–
U, V, W
M8
3.0
100 (4/0)
CB100-S8
DU, DV, DW
M6
3.0
5.5 (10)
R5.5-6
M8
9.0 to 11.0
100 (4/0)
100-8
Converter
P, N
M10
12 to 20
Bus bar attached
to the converter
–
L1, L2, L3
M10
12 to 20
60 (2/0)
R60-10
1, 2
M10
12 to 20
60 (2/0)
R60-10
CN101
(L1C, L2C)
–
(Connector)
–
1.25 (16)
–
B1, B2
M10
12 to 20
14 (6)
R14-10
M8
9.0 to 11.0
60 (2/0)
R60-8
SGDV-201H
SGDV-
COA3GAA
SERVO-
PACK
P, N
M10
12 to 20
Bus bar attached
to the converter
–
U, V, W
M10
30.0
100 (4/0)
R100-10
DU, DV, DW
M6
3.0
5.5 (10)
R5.5-6
M8
9.0 to 11.0
100 (4/0)
100-8
Converter
P, N
M10
12 to 20
Bus bar attached
to the converter
–
L1, L2, L3
M10
12 to 20
100 (4/0)
R100-10
1, 2
M10
12 to 20
100 (4/0)
R100-10
CN101
(L1C, L2C)
–
(Connector)
–
1.25 (16)
–
B1, B2
M10
12 to 20
14 (6)
R14-10
M8
9.0 to 11.0
100 (4/0)