Event ID
Description
PK: Not user relevant
ZINFO1: Error type
1: SDB parser error
2: Configured address already used
3: Mapping error
ZINFO2: Slot (0=cannot be determined)
DatID: Not user relevant
0xEB04
SLIO-Bus: Multiple configuration of a periphery address
ZINFO1: Periphery address
ZINFO2: Slot
DatID: Input
DatID: Output
0xEB05
System SLIO error: Bus structure for isochronous process image not suitable
PK: Not user relevant
ZINFO2: Slot (0=cannot be determined)
DatID: Not user relevant
0xEB06
System SLIO error: Timeout with the isochronous process image
0xEB10
System SLIO error: Bus error
PK: Not user relevant
ZINFO1: Error type
96: Bus enumeration error
128: General error
129: Queue execution error
130: Error interrupt
ZINFO2: Error on bus enumeration error (ZINFO1)
DatID: Not user relevant
0xEB11
System SLIO error: Error during bus initialization
PK: Not user relevant
DatID: Not user relevant
0xEB20
System SLIO error: Interrupt information undefined
0xEB21
System SLIO error: Accessing configuration data
ZINFO2: Not user relevant
ZINFO3: Not user relevant
DatID: Not user relevant
0xEC02
EtherCAT: configuration warning
ZINFO1: Error code
1: Number of slave stations is not supported
2: Master system ID invalid
System 300S
+
System specific event IDs
HB140 | CPU | 315-4PN23 | en | 18-02
188