4.
A value to be read of a read job may be found in
JOB_OVAL
in the instance DB at
address 28.
Continuous count:
Job
Valid range
Writing
counter
directly
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing the
load value
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing
comparison value
-2147483648 (-2
31
) ... +2147483647 (2
31
-1)
Writing
hysteresis
0 ... 255
Writing
pulse duration
*
0 ... 510ms
Single/periodic count, no main count direction:
Job
Valid range
Writing
counter
directly
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing the
load value
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing
comparison value
-2147483648 (-2
31
) ... +2147483647 (2
31
-1)
Writing
hysteresis
0 ... 255
Writing
pulse duration
*
0 ... 510ms
Single/periodic count, main count direction up:
Job
Valid range
End value
2 ... +2147483646 (2
31
-1)
Writing
counter
directly
-2147483648 (-2
31
) ...
end value
-2
Writing the
load value
-2147483648 (-2
31
) ...
end value
-2
Writing
comparison value
-2147483648 (-2
31
) ...
end value
-1
Writing
hysteresis
0 ... 255
Writing
pulse duration
*
0 ... 510ms
Single/periodic count, main count direction down:
Job
Valid range
Writing
counter directly
2 ... +2147483647 (2
31
-1)
Writing the
load value
2 ... +2147483647 (2
31
-1)
Writing
comparison value
1 ... +2147483647 (2
31
-1)
Writing
hysteresis
0 ... 255
Permitted value range for
JOB_VAL
VIPA System 300S
+
Deployment I/O periphery
Counter > SFB 47 - COUNT - Counter controlling
HB140 | CPU-SC | 313-5BF23 | en | 19-01
115