5.10 Accessing the web server
There is a web server, which can be accessed via the IP address of the Ethernet PG/OP
channel with an Internet browser. At the web page information about the CPU and its
connected modules can be found.
Chap. 5.7 ‘Hardware configuration - Ethernet
It is assumed that there is a connection between PC and CPU with Internet browser via
the Ethernet PG/OP channel. This may be tested by Ping to the IP address of the
Ethernet PG/OP channel.
The web page is built dynamically and depends on the number of modules, which are
connected to the CPU. The web page only shows information. The shown values cannot
be changed.
Here order number, serial number and the version of firmware and hardware of the CPU
are listed. [Expert View] takes you to the advanced "Expert View".
Info - Expert View
Runtime Information
Operation Mode
STOP
CPU: Status information
Mode Switch
RUNP
System Time
01.09.09 00:35:30:812
CPU: Date, time
OB1-Cycle Time
cur = 0us, min = 0us, max = 0us, avg =
0us
CPU: Cyclic time:
min = minimum
cur = current
max = maximum
avg = average
Interface Information
X2 (RS485/COM1)
MPI
Operating mode RS485
n
MPI: MPI operation
X3 (RS485/COM2)
PtP
n
PtP: point to point operation
X5
PG/OP Ethernet Port
Access to the web server
Structure of the web page
Info - Overview
VIPA System 300S
+
Deployment CPU 313-5BF23
Accessing the web server
HB140 | CPU-SC | 313-5BF23 | en | 19-01
61