background image

General

1.1  Copyright 

©

 VIPA GmbH

This document contains proprietary information of VIPA and is not to be disclosed or used

except in accordance with applicable agreements.

This material is protected by the copyright laws. It may not be reproduced, distributed, or

altered in any fashion by any entity (either internal or external to VIPA), except in accord-

ance with applicable agreements, contracts or licensing, without the express written con-

sent of VIPA and the business management owner of the material.

For permission to reproduce or distribute, please contact: VIPA, Gesellschaft für Visuali-

sierung und Prozessautomatisierung mbH Ohmstraße 4, D-91074 Herzogenaurach, Ger-

many

Tel.: +49 9132 744 -0

Fax.: +49 9132 744-1864

EMail: info@vipa.de

http://www.vipa.com

Every effort has been made to ensure that the information contained in

this document was complete and accurate at the time of publishing. Nev-

ertheless, the authors retain the right to modify the information.

This customer document describes all the hardware units and functions

known at the present time. Descriptions may be included for units which

are not present at the customer site. The exact scope of delivery is

described in the respective purchase contract.

Hereby, VIPA GmbH declares that the products and systems are in compliance with the

essential requirements and other relevant provisions. Conformity is indicated by the CE

marking affixed to the product.

For more information regarding CE marking and Declaration of Conformity (DoC), please

contact your local VIPA customer service organization.

VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V,

System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft

für Visualisierung und Prozessautomatisierung mbH.

SPEED7 is a registered trademark of profichip GmbH.

SIMATIC, STEP, SINEC, TIA Portal, S7-300 and S7-400 are registered trademarks of

Siemens AG.

Microsoft and Windows are registered trademarks of Microsoft Inc., USA.

Portable Document Format (PDF) and Postscript are registered trademarks of Adobe

Systems, Inc.

All other trademarks, logos and service or product marks specified herein are owned by

their respective companies.

Contact your local VIPA Customer Service Organization representative if you wish to

report errors or questions regarding the contents of this document. If you are unable to

locate a customer service centre, contact VIPA as follows:

All Rights Reserved

CE Conformity Declaration

Conformity Information

Trademarks

Information product sup-

port

VIPA HMI

General

Copyright 

©

 VIPA GmbH  

HB160 | TP-smart | H41-71A41-0 | en | 18-04

 

4

Summary of Contents for TP304-SM

Page 1: ...TP smart H41 71A41 0 Manual HB160 TP smart H41 71A41 0 en 18 04 VIPA HMI smartPanel TP304 SM www vipa com en service support manuals...

Page 2: ...H41 71A41 0_000_TP304 SM 1 EN 2018 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com...

Page 3: ...21 3 3 Connection to a PLC system 24 3 4 Operating system Windows Embedded Compact 7 25 3 4 1 General 25 3 4 2 Structure 26 3 5 Integrated server 28 3 5 1 General 28 3 5 2 ftp server 29 3 5 3 Telnet s...

Page 4: ...ive purchase contract Hereby VIPA GmbH declares that the products and systems are in compliance with the essential requirements and other relevant provisions Conformity is indicated by the CE marking...

Page 5: ...ndows Embedded Compact 7 The manual is targeted at users who have a background in automation technology The manual consists of chapters Every chapter provides a self contained description of a specifi...

Page 6: ...nt n installation department n commissioning n operation CAUTION The following conditions must be met before using or commis sioning the components described in this manual Hardware modifications to t...

Page 7: ...that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection devices and m...

Page 8: ...le for monitoring and controlling of process cycles n Windows Embedded Compact 7 n Movicon 11 CE Standard 4096 I O Bytes n Processor ARM Cortex A8 1GHz n Flash memory 4GB RAM 512MB DDR n RS232 RS422 R...

Page 9: ...tive area Touch Screen 1 USB A interface USB 2 0 2 RJ45 jack for Ethernet communication LAN 3 RS232 RS422 RS485 interface COM 4 Slot for DC 24V voltage supply Front view Bottom view VIPA HMI Hardware...

Page 10: ...ellow Description on off no link blinks on 100Mbit s link blinks off 10Mbit s link 9 pin SubD plug n Interface is compatible to the COM interface of a PC n Logical signals as voltage levels n Point to...

Page 11: ...stems are available for the smartPanel n 512MB work memory RAM n 4GB user memory Flash n USB storage media using Host USB A interface Every Touch Panel has a work memory with a size of 512MB The work...

Page 12: ...B 136 x 96 mm The degrees of protection are only guaranteed when the following is observed Material thickness at the mounting cut out 1 5 6mm The deviation from the plane for the panel cut out is 0 5m...

Page 13: ...tion voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14...

Page 14: ...ulses with Surge an appropriate external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Technical data Order no H41 71A41 0 Type s...

Page 15: ...232 RS422 RS485 COM1 connector Sub D 9 pin male Serial COM2 COM2 connector Number of USB A interfaces 1 USB A connector USB A host Number of USB B interfaces USB B connector Number of ethernet interfa...

Page 16: ...imensions Front panel 147 mm x 107 mm x 5 mm Rear panel 133 mm x 93 mm x 29 mm Installation cut out Width 136 mm Height 96 mm Minimum 1 5 mm Maximum front panel thickness 6 mm Net weight 291 g Weight...

Page 17: ...martPanel into the openings The screws should point in the direction of the front panel 3 Screw the screws from the other side with the crosstip screwdriver 5 n For the cabling of the DC 24V power sup...

Page 18: ...during operation the device must not be laid open to direct sun light After opening the control cabinet or desk there are parts with pos sible dangerous voltage available For all signal connections o...

Page 19: ...are otherwise no update is executed 1 Go to www vipa com 2 Click on Service Support Downloads Firmware 3 Via HMI navigate to your smartPanel download the ZIP file for the update process and unzip the...

Page 20: ...rt of the smartPanel The update process starts automatically and can take several minutes After successful update the message Process completed successfully appears A log file lastupdate log is genera...

Page 21: ...under Change Settings you can set a password for the Startup Manager The password will be requested when interrupting the start countdown or before closing the Startup Managers by Exit By default no...

Page 22: ...adjust a delay time 0 by using the buttons and 5 seconds are default Via Program start with you can add programmes which have to start automatically 1 Select start and assign a name for the program 2...

Page 23: ...or the back light the local settings and the LAN settings will be saved by Backup in Flashdisk Backup The name of the backup file is backup bkv Which settings will be saved and the storage location ar...

Page 24: ...time version of the HMI SCADA project engineering platforms your project is run able n By using the according communication driver the smartPanel supports connecting options to the PLC via field bus...

Page 25: ...By tapping on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the dragging that selects the touched objects The windows can be moved v...

Page 26: ...ccess to all components of your smartPanel such as applications system settings file browser etc 2 Open applications For every open application a button can be found in the task bar There is no button...

Page 27: ...ock The software keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides th...

Page 28: ...e within a network Some servers only allow access by means of entering User name and Pass word The following login data are used standardly User name wince Password vipatp Per default the following se...

Page 29: ...p sites 2 Restart the Internet Explorer The settings are saved Below is explained how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and your smartPane...

Page 30: ...llowing into the address bar telnet IP address When the connection is established the smartPanel asks for the user name and the password 2 Enter the following Login wince Password vipatp entry is hidd...

Page 31: ...u can deactivate all safety attitudes with the VNC server you should use these exclusively for start up For this reason the VNC server is on delivery deactivated Due to software reasons VIPA does not...

Page 32: ...the smartPanel res of websites in the smartPanel The administrative access to the http server happens via Ethernet from the PC by setting the IP address of the smartPanel with attached Admin type Usi...

Page 33: ...n be listed by the command net view PC Name n For example net view testserver lists all shared resources of the network PC test server To test the physical connection a PING to the IP address of the n...

Page 34: ...ed to network printer The printer may now be accessed as network printer For example you can print the content of the current directory using dir network printer The listing command for all network co...

Page 35: ...nt ways n Electromagnetic fields RF coupling n Magnetic fields with power frequency n Bus system n Power supply n Protected earth conductor Depending on the spreading medium lead bound or lead free an...

Page 36: ...n Sparking lines sparking plugs collector of electric motors welding devices In the most times it is enough to take care of some elementary rules to guarantee the EMC Please regard the following basi...

Page 37: ...ial EMC actions Consider to wire all inductivities with erase links Please consider luminescent lamps can influence signal lines n Create a homogeneous reference potential and ground all electrical op...

Page 38: ...even in case of an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts have t...

Page 39: ...ups Group A Group B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed in...

Page 40: ...equipotential bonding conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is connected...

Page 41: ...over Do not connect the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to att...

Page 42: ...iode using a varistor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutral co...

Page 43: ...n grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunches...

Reviews: