background image

2.

Enter the following:
Login: 

wince

Password:

 vipatp

 (entry is hidden)

ð

After entering valid user data a command line for entries

appears:

By entering 

Exit

 res. closing the window you may terminate the

Telnet connection at any time.

After establishment of a Telnet connection the Panel PC provides you

with commands. A list of possible commands with a short description

is available via the command help. By beginning with "help" before a

command you receive help to this command.

3.6.5  VNC server

The Touch Panel has an integrated VNC server (virtual network con-

trol) that allows the total control of the Touch Panel with a PC via net-

work. For this, a window displays the current Touch Panel content for

remote control. Operation is performed via PC keyboard and mouse.

Condition for the VNC communication is, that the VNC server is

started on the Touch Panel and a VNC client on the PC. You may

download a VNC client as freeware from internet.

Commands

VIPA HMI Touch Panel

Deployment Touch Panel

Integrated Server > VNC server

HB160 | TP | 62K-JEE0 | GB | 14-38

 

43

Summary of Contents for VIPA 62K-JEE0

Page 1: ...TP 62K JEE0 Manual HB160 TP 62K JEE0 GB 14 38 VIPA HMI Touch Panel...

Page 2: ...62K JEE0_000_TP610C 1 GB 2014 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 email info vipa com Internet www vipa com...

Page 3: ...to a PLC system 32 3 4 Operating system Windows Embedded CE 6 0 Prof 32 3 4 1 General 32 3 4 2 Structure 34 3 5 Communication via ActiveSync 38 3 6 Integrated Server 40 3 6 1 General 40 3 6 2 ftp serv...

Page 4: ...very effort has been made to ensure that the information contained in this document was complete and accurate at the time of publishing Nevertheless the authors retain the right to modify the informat...

Page 5: ...efax 49 9132 744 1204 EMail documentation vipa de Contact your local VIPA Customer Service Organization representa tive if you encounter problems with the product or have questions regarding the produ...

Page 6: ...ty information The Touch Panels are constructed and produced for n VIPA CPUs 01x 11x 21x 31x 51x and S7 300 400 from Sie mens n communication and process control n industrial applications n operation...

Page 7: ...ied out when the system has been disconnected from power Installation and hardware modifications only by prop erly trained personnel The national rules and regulations of the respective country must b...

Page 8: ...at have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the conse quent implementation of protection devices and me...

Page 9: ...essor Xscale 800MHz n Work memory 128Mbyte n User memory 4GB n 3800Mbyte memory for user data n CF Card II and MMC SD card slot n RS232 RS422 485 MPI PROFIBUS DP slave Ethernet USB A and USB B interfa...

Page 10: ...ace COM 2 2 RS232 interface COM 1 3 MPI PROFIBUS DP RS485 interface 4 2x Host USB A interfaces 5 Slave USB B interface 6 RJ45 jack for Ethernet communication 7 RJ45 jack for Ethernet communication 8 S...

Page 11: ...ces between the 4 cores n Serial bus connection in 4 wire technology using full duplex mode n Data communications up to a max distance of 500m n Data communication rate up to 115 2kBaud n Serial bus c...

Page 12: ...nterface USB mouse keyboard stick or USB hard discs can be connected For project transfer with Microsoft ActiveSync a programming cable can be connected using the Slave USB B interface The USB A inter...

Page 13: ...ls within consignment As internal permanent storage medium every Touch Panel has a Micro SD card with a size of 4Gbyte about 3800Mbyte user data After the start of Windows CE this memory is listed as...

Page 14: ...ugging the security flap additionally snaps into position above the plugged memory card 2 4 Dimensions For the installation of the Touch Panel in control cabinets and desks the following dimensions ar...

Page 15: ...ing cut out 1 5 6mm The deviation from the plane for the panel cut out is 0 5mm This condition must be fulfilled for the mounted HMI device Permissible surface roughness in the area of the seal 120 m...

Page 16: ...cess level electrically isolated Insulation resistance Insulation voltage to reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental condi...

Page 17: ...AM 1kHz EN 61000 4 4 Burst degree of severity 3 EN 61000 4 5 Surge installation class 3 Due to the high energetic single pulses with Surge an appropriate external protective circuit with lightning pr...

Page 18: ...ontrols Touchscreen resistive Touch function Single Touch Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP RS485 isolated MPI PROFIBUS DP connector Sub D 9 pin female Serial...

Page 19: ...Housing Protection type Material die cast aluminum Mounting via integrated pivoted lever Protect type front side IP 65 Protect type back side IP 20 Dimensions Front panel 304 mm x 233 mm x 7 5 mm Rea...

Page 20: ...y user data 3800 MB SD MMC Slot CF Card Slot Typ II CFast Slot Time Real time clock buffered Clock buffered period min 6 w Type of buffering Vanadium Rechargeable Lithium Battery Load time for 50 buff...

Page 21: ...y permitted range DC 20 4 28 8 V Reverse polarity protection Current consumption no load operation 0 51 A Current consumption rated value 0 7 A Inrush current 7 A I t 0 25 A s Power loss 12 2 W Status...

Page 22: ...ss 6 mm Weight 3251 g Environmental conditions Operating temperature 0 C to 50 C Storage temperature 20 C to 60 C Certifications UL508 certification in preparation VIPA HMI Touch Panel Hardware descri...

Page 23: ...t fronts the Touch Panel requires the following front plate cutting Touch Panel W x H in mm 62K JEE0 287 x 217 The fixing technique is integrated in the casing of the Touch Panel and accessible via th...

Page 24: ...the CageClamps like this 1 Round opening for wires 2 Locking orange for screwdriver 3 Test point for 2mm test tip The picture on the left side shows the cabling step by step from top view 1 For cablin...

Page 25: ...1 VIPA Startup Manager As soon as the Touch Panel is provided by power supply the Touch Panel starts with the user area of the VIPA Startup Manager On delivery the button Advanced is shown on the star...

Page 26: ...tools With this button you can return to the user area With the button Control Panel or via Start Settings Control Panel the system settings like brightness and contrast of the display can be preset o...

Page 27: ...the Touch Panel starts with the Startup Manager the listed functions under Copy and Exe cute are executed and the program marked with Autostart will be executed n If Enable User Interface is disabled...

Page 28: ...ord n The administrator area can be protected by a password Here you can enter respectively change this password n If you click within the user area on the button Advanced and a password is defined yo...

Page 29: ...Files can be added by With the corresponding file is removed from the list With the file can be downloaded n With Autostart a program from the program list can be selected which will be started delay...

Page 30: ...h Panel start the tool Com2 Configuration via the button Control Panel Configuration COM2 RS422 485 n In the opening dialog window you can activate the RS485 or the RS422 interface n Default off Contr...

Page 31: ...e the interface could be set up on DP Slave It is possible to set up the DP slave with the tool via soft ware if the hardware of the Touch Panel does not support this In this case MPI does not work ei...

Page 32: ...nicates with the according PLC and reacts to the application courses in the PLC according to the configured processes Via dialogues configured before process values may be monitored graphically altere...

Page 33: ...ing on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the drag ging that selects the touched objects Characteristics with Windows Embe...

Page 34: ...nd in the task bar There is no button for minimizing The switch between the appli cations is performed via this buttons 3 Network connection As soon as your Touch Panel is connected via Ethernet you c...

Page 35: ...e note that can exclusively be entered via the software keyboard Keyboard At pushed SHIFT key Keyboard Large KB VIPA HMI Touch Panel Deployment Touch Panel Operating system Windows Embedded CE 6 0 Pro...

Page 36: ...dialog win dows for the display properties opens Here you can change the settings for the monitor options For example you can adjust the brightness and contrast via the register Settings n Calibrate...

Page 37: ...can be found under Start Settings Control Panel MPI Configuration n HSA Here you set the highest MPI address highest station address Within a MPI network the highest MPI address must be identical n TS...

Page 38: ...you have to install it on the PC ActiveSync is freeware and can be down loaded from www microsoft de 1 Download the ActiveSync from the Microsoft website and start the file MSASYNC EXE 2 Start the in...

Page 39: ...e Touch Panel is recognized and the dialog window new partnership opens 2 Choose yes for fixing a partnership and push Next 3 In the opening window de activate all synchronization settings and click o...

Page 40: ...e server A client is an application that uses the service of a server within a net work For example a web browser is a client because at every call of a website it sends a request to a web server and...

Page 41: ...how to establish of a ftp connection between a Windows based PC with Windows Explorer as ftp client and your Touch Panel 1 Connect your Touch Panel with the network where your PC is a member via an Et...

Page 42: ...equires the following steps 1 Start the web browser at your PC and enter the following into the address bar IP address webadmin 2 Enter the following into the authentification n User name wince n Pass...

Page 43: ...efore a command you receive help to this command 3 6 5 VNC server The Touch Panel has an integrated VNC server virtual network con trol that allows the total control of the Touch Panel with a PC via n...

Page 44: ...et connection by entering the command winvnc in the command console with an active Telnet connection 3 Now start the VNC client vncviewer exe on your PC 4 Click on Options and deactivate the field Emu...

Page 45: ...er To test the physical connection a PING to the IP address of the network PC can be executed if there are problems while contacting the network PC The connection of a local name at the Touch Panel wi...

Page 46: ...For example you can print the content of the current directory using dir network printer The listing command for all network connections of your Touch Panel is net use You can terminate already assig...

Page 47: ...PC 4 Copy the os file to your storage medium 5 Unzip the zip file with directory structure to your storage medium 6 Switch on the power supply of your Touch Panel and plug in the external storage medi...

Page 48: ...ents and meets high demands on the EMC Neverthe less you should project an EMC planning before installing the compo nents and take conceivable interference causes into account Electromagnetic interfer...

Page 49: ...er sonnel n Contactors Inductive coupling Inductive or magnetic coupling occurs between two current active line loops The magnetic flows associated with the cur rents induct interference vol tages The...

Page 50: ...h the cabinet Use metallic or metallised plug cases for isolated data lines n In special use cases you should appoint special EMC actions Consider to wire all inductivities with erase links Please con...

Page 51: ...orrosion e g with grease n Moveable grounding parts e g cubicle doors have to be con nected via flexible ground strips The ground strips should be short and have a large surface because the surface is...

Page 52: ...able lightning pro tection and grounding regulations when installing exterior cables CAUTION Where cables and signal lines for PLC equipment are installed outside of buildings the conditions for inter...

Page 53: ...ion n The equipotential bonding conductor should be installed in such a manner that it includes the smallest surface between the bonding conductor and the signal lines Screening is one method commonly...

Page 54: ...ttach the screens to the screening rail directly at the point where the cables enter the enclosure The screening conductor must be continued to the module without interruption however it must not be c...

Page 55: ...ist of incandescent lights e g LINESTRA lamps Avoid using fluorescent lamps as these lamps can cause interference If you can not avoid using fluorescent lamps you should implement the steps outlined i...

Page 56: ...grounded by means of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunches Po...