VS-616PS5 Programming Manual
49
F
Option Parameters
F1
PG Option Set-up
These parameters set up the Speed feedback pulse generator (PG).
Setting Range:
0 to 10000
Factory Default:
30
This parameter sets the number of PG pulses per motor revolution (pulses/rev). Enter
the PPR of the hall sensor signals HS4 & HS5 for Hall sensor only feedback
(F8-
01=1).
Use the encoder PPR for motors using encoders
(F8-01=0)
. Consult the fac-
tory when using encoders with greater than 4096 PPR.
Selects the stopping method when a disconnected PG is detected.
Selects the stopping method when an overspeed condition is detected.
Selects the stopping method when excessive speed deviation is detected.
F1-01 PG Pulses per Revolution
Q
F1-02 PG Disconnection Detection Stopping Method
B
Setting
Description
0
Ramp to stop - according to C1-02. (Declaration time 1).
1
Coast to stop
(factory default)
.
2
Fast-stop - according to C1-09.
3
Alarm flashes, operation continues.
F1-03 Overspeed Detection Stopping Method
B
Setting
Description
0
Ramp to stop - according to C1-02 (Declaration time 1).
1
Coast to stop
(factory default)
.
2
Fast-stop - according to C1-09.
3
Alarm flashes, operation continues.
F1-04 PG Deviation Detection Stopping Method
B
Setting
Description
0
Ramp to stop - according to C1-02 (Declaration time 1).
1
Coast to stop.
2
Fast-stop - according to C1-09.
3
Alarm flashes, operation continues
(factory default).
Section F: Option Parameters
F1 PG Option Set-up