4.2 Settings on Welding Source Panel
4-11
HW0480311
HW0480311
4.2.7
Checking the Flow Amount of Shielding Gas
The shielding gas flow amount can be checked.
Press the button
"Gas" button. The LED indicator lamp above the "GAS" button lights and
the gas flows for 20 seconds.
Press the button again during gas checking to stop the gas flow.
The checking time of the gas flow amount can be adjusted by change in the numerical value
of C parameter C00, while, the default setting is 20 seconds (unit: second).
Press the button
"Record" for 3 seconds or more to save the changed value.
4.2.8
Selecting Feeding Motor
The feeding motor can be selected by change in the numerical value of C parameter C09.
C09: 0 Print servo (Default setting)
C09: 1 Servo torch
C09: 2 4-roller servo
(YWE-WF340MELC)
Press the button
"Record" button for 3 seconds or more to save the changed value.
To validate the change in setting, turn OFF the welding source and ON again after saving the
conditions.
Do not turn OFF the breaker until the 7-segment LED indicators are lit again when the
“Record” button was pressed.
Do not turn OFF the breaker until the 7-segment LED indicators are lit again when the
“Record” button was pressed.
• Welding performance will be unsatisfactory, since the wire cannot be
fed at the wire feeding speed as instructed by the command value
unless the feeding motor is set correctly.
• The change in the motor setting will be first reflected when the welding
source is restarted (turned OFF
Æ
ON) after saving the conditions.
15
14
NOTE
14
NOTE
CAUTION
45/129