11
Replace Table D.1 on page 328
D.2 European Standards
Figure D.1 CE Mark
The CE mark indicates compliance with European safety and environmental regulations. It is required for engaging in business
and commerce in Europe.
European standards include the Machinery Directive for machine manufacturers, the Low Voltage Directive for electronics
manufacturers, and the EMC guidelines for controlling noise.
This drive displays the CE mark based on the EMC guidelines and the Low Voltage Directive.
• Low Voltage Directive: 2006/95/EC
• EMC Guidelines: 2004/108/EC
Devices used in combination with this drive must also be CE certified and display the CE mark. When using drives displaying
the CE mark in combination with other devices, it is ultimately the responsibility of the user to ensure compliance with CE
standards. After setting up the device, verify that conditions meet European standards.
u
u
CE Low Voltage Directive Compliance
This drive has been tested according to European standard IEC61800-5-1, and it fully complies with the Low Voltage Directive.
To comply with the Low Voltage Directive, be sure to meet the following conditions when combining this drive with other
devices:
n
n
Area of Use
Do not use drives in areas with pollution higher than severity 2.
n
n
Installing Fuses on the Input Side
Always install input fuses. Select fuses according to the table below.
WARNING!
Fire Hazard. Install adequate branch circuit protection according to applicable local codes and this manual. Failure to comply
could result in fire and damage to the drive or injury to personnel. The device is suitable for use on a circuit capable of delivering not more
than 100,000 RMS symmetrical amperes, 240 Vac (200 V class) and 480 Vac (400 V class), when protected by branch circuit protection
devices specified in this manual.
Branch circuit protection shall be provided by any of the following: Non-time delay Class J, T, or CC fuses sized at 300% of the drive input
rating, or Time delay Class J, T, or CC fuses sized at 175% of the drive input rating, or MCCB sized at 200% maximum of the drive input
rating.
Table D.1 Recommended Input Fuse Selection
Model CIMR-Z
o
o
Manufacturer: Bussmann
Model
Fuse Ampere Rating (A)
Three-Phase 200 V Class
2A0011
FWH-40B
40
2A0017
FWH-50B
50
2A0024
FWH-80B
80
2A0031
FWH-100B
100
2A0046
FWH-150B
150
2A0059
FWH-175B
175
2A0075
FWH-225A
225
2A0088
FWH-225A
225
2A0114
FWH-250A
250
2A0143
FWH-275A
275
2A0169
FWH-350A
350
2A0211
FWH-400A
400
2A0273
FWH-450A
450
2A0343
FWH-600A
600
D.2 European Standards
342
YASKAWA ELECTRIC TOEP C710616 45B YASKAWA AC Drive – Z1000 User Manual
11 Replace Table D.1 on page 328
20
YASKAWA TOEP YAISUP 04A YASKAWA AC Drive – Z1000 User Manual Supplement