i.9
Standards Compliance
u
European Standards
Figure i.57 CE Mark
The CE mark indicates that a product is in compliance with applicable European Directives for safety and environmental
regulations. It is required for engaging in business and commerce in Europe.
The applicable European Directives for this product are as follows. We declared the CE marking based on the harmonized
standards in
Table i.32 European Directives
Applicable European Directive
Applicable Harmonized Standards
Low Voltage Directive (2014/35/EU)
IEC/EN 61800-5-1: 2007
EMC Guidelines (2014/30/EU)
EN 61800-3:2004+A1:2012
The user(s) is solely responsible for ensuring that the end products used with this drive comply with all applicable European
directives and with other national regulations (if required).
u
CE Low Voltage Directive Compliance
This drive has been tested according to European standard IEC/EN 61800-5-1:2007, and it fully complies with the Low Voltage
Directive.
To comply with the Low Voltage Directive, be sure to meet the following conditions when combining this drive with other
devices:
n
Area of Use
Do not use drives in areas with pollution higher than degree 2 and overvoltage category 3 in accordance with IEC/EN 60664.
n
Grounding
The drive is designed to be used in T-N (grounded neutral point) networks. If installing the drive in other types of grounded
systems, contact your Yaskawa representative for instructions.
n
Guarding Against Harmful Materials
When installing IP00/Open Type enclosure drives, use an enclosure that prevents foreign material from entering the drive
from above or below.
u
EMC Guidelines Compliance
When EMC is a concern for drives with internal EMC filters and the network is grounded symmetrically, install the EMC
filter screw to the ON position and enable the internal EMC filter.
Drives ship from the factory with EMC filter screws installed in the OFF position.
Drives with internal EMC filters ( Z
oo
E
oooo
and Z
oo
W
oooo
) are tested according to European standards IEC/
EN 61800-3: 2004+A1: 2012 and comply with EMC guidelines.
Note:
Drives with customized specifications A and P are not compatible.
Refer to Model Number on page 14
specifications.
n
Internal EMC Filter Installation
Installation Method
Verify the following installation conditions to ensure that other devices and machinery used in combination with drive models
Z
oo
E
oooo
and Z
oo
W
oooo
also comply with EMC guidelines.
1.
Place the drive in the enclosure.
i.9 Standards Compliance
80
YASKAWA ELECTRIC TOEP C710636 11E Z1000U HVAC MATRIX Drive Quick Start Guide