12
GB
O R I G I N A L I N S T R U C T I O N S
Warning! Do not touch hot glue. High temperatures can cause burns.
Heater interruption occurs after releasing the pressure on the trigger.
Due to the thermal inertia, adhesive may still be released from the nozzle for some time after the trigger pressure is released.
Pressing the switch will turn o
ff
the gun. The power light and the lamp that illuminates the gun nozzle will turn o
ff
.
Let the gun cool down, then proceed to maintenance.
Hints useful for operation of the product
Do not apply glue on products that are sensitive to high temperatures.
Foam products (e.g. foamed polystyrene) may be bonded provided they have protective coating. It is forbidden to apply glue directly on foam products!
Bonded surfaces must be clean, dry and degreased. If the bonded surface permits, it is recommended to make it matt e.g. by using sand paper. This will
increase roughness of surface resulting in better contact of glue with bonded surface.
For large surfaces, point gluing is recommended. This consists in evenly distributing points of glue on entire surface. The glue upon
fl
owing out of nozzle
starts to cure fast; this should be taken into account when bonding large surfaces. If it is possible, materials that require using large quantity of glue should
be bonded in stages.
When bonding textile or similar materials, apply glue in “S” pattern.
MAINTENANCE AND OVERHAUL
ATTENTION! Before any adjustment, technical service or maintenance operations unplug the tool. Once the operations have been
fi
nished, the technical
conditions of the tool must be assessed by means of external evaluation and inspection of the following elements: body and handle, conductor with a plug
and de
fl
ection, functioning of the electric switch, patency of ventilation slots, sparking of brushes, noise level of functioning of bearings and gears, start-up
and smoothness of operation. During the guarantee period, the user cannot dismantle the electric tools or change any sub-assemblies or elements, since
it will cancel any guarantee rights. All irregularities detected at overhaul or during functioning of the tools are a signal to have the tool repaired at a service
shop. Once the functioning has been concluded, the casing, ventilation slots, switches, additional handle and protections must be cleansed with a stream of
air (at a pressure not exceeding 0.3 MPa), with a brush or a cloth without any chemical substances or cleaning liquids. Tools and handles must be cleansed
with a clean cloth.