14
O R I G I N A L I N S T R U C T I O N S
EN
again or waiting for approx. 5 seconds will trigger the return to normal display.
Pressing and holding down the “SET” button for approx. 2 seconds allows changing the set temperature. „
O
C” or „
O
F” temperature
unit indicator will
fl
ash, the setting can be changed using the arrow buttons. The setting entered will be saved after pressing the
“SET” button again or waiting 10 seconds after the setting was changed.
Pressing and holding down the “SET” buttons and an arrow pointing down simultaneously for approx. 3 seconds will start the
parameter programming mode, and „
O
C” or „
O
F” temperature unit indicator will
fl
ash at the same time. Parameters can be selected
by using arrow buttons, and then press and release the “SET” button to display its value. Values can be changed using arrow but-
tons. New settings should be acknowledged by pressing and releasing the “SET” button. It will also cause an automatic transition
to the next parameter display. Exit from the parameter programming mode takes place after simultaneous pressing and holding
down the “SET” buttons and the upward pointing arrow. If 15 seconds have elapsed since the last pressing of button. The control
panel will automatically end its operation in the parameter programming mode and all settings will be saved.
Warning!
Product’s operating parameters have been split into two groups. One is available in an open mode described above and
the other in a hidden mode, which requires a separate procedure to change them. Both group parameters should not be changed
without reading and understanding their meaning. Do not change any parameter values below / above the limit value mentioned in
this manual. Setting the parameters outside the operating range may lead to improper operation of the product, which may result
in permanent damage to the product, cause
fi
re or electric shock.
The manufacturer is not liable for damages resulting from the change of parameters beyond the limit values.
Parameter in the hidden mode can be changed in the following way. Pressing and holding down the “SET” buttons and an arrow
pointing down simultaneously for approx. 3 seconds will start the parameter programming mode, and „
O
C” or „
O
F” temperature
unit indicator will
fl
ash at the same time. Release both buttons and then press the same buttons again and hold them down for
approx. 7 seconds. L2 will be displayed and the
fi
rst parameter from the menu labelled “Hy” will be displayed. Parameters should
be changed and saved according to the procedure described for the open mode.
If none parameter is visible in the open mode, then the indicator will display the “nP” symbol after approx. 3 seconds. In this case,
all parameters are in the hidden mode. Parameters can be transferred between both modes. In the hidden mode, press the button
marked “SET” and the arrow pointing down simultaneously. If the parameter is already visible in the open mode, then when view-
ing parameters in the hidden mode, the symbol of a character separating the integer part from the decimal part of an indication
next to the parameter symbol will be displayed.
Pressing and holding down the button marked with the snow
fl
ake and drop of water symbols for about 2 seconds will trigger
manual activation of the cooling chamber defrosting process.
Buttons will be locked after the simultaneous pressing and holding down the two arrow keys for approx. 3 seconds. “OF” symbol
will be displayed. After locking the buttons, any pressing and holding down any button for approx. 3 seconds will display the “OF”
indication. Buttons can be unlocked by simultaneous pressing and holding down the two arrow keys for approx. 3 seconds. After
unlocking, the “on” indication will be displayed.
List of parameters
Note! The complete list of parameters is listed below. Some parameters may not be available in the control panel version installed
in the product.
Parameters related to adjustment
Hy - tolerance (0.1
O
C ~ 25
O
C / 1
O
F ~ 45
O
C) - operating temperature tolerance. A product’s compressor will start when the
temperature reaches the sum of operating temperature plus the tolerance. The compressor will turn o
ff
when the temperature
equals the set operating temperature.
LS - minimum temperature (from -55
O
C / -67
O
C) - minimum operating temperature.
US - maximum operating temperature (up to 99
O
C / +99
O
F) - maximum operating temperature.
Note! Both of the above parameters should not be set beyond the range mentioned in the user manual and visible on the product
nameplate.
ot -
fi
rst sensor calibration (-9.9 ~ +9.9
O
C / -17 ~ +17
O
F) - it allows setting the
fi
rst sensor temperature o
ff
set .
P2 - presence of evaporation sensor - n = - absent; y = - present.
oE - second sensor calibration (-9.9 ~ +9.9
O
C / -17 ~ +17
O
F) - it allows setting the second sensor temperature o
ff
set .
od - output activation delay during the start-up (0 - 99 min.) - parameter determines the delay time of output activation after starting
the instrument.
AC - compressor operation cycle (0 - 50 min.) - time between stopping and re-starting the compressor operation.
Cy - switching on the compressor with defective sensor (0 - 99 min.) - time of compressor operation in case of the defective
thermostat sensor. In case of Cy = 0 setting, the compressor is always on.
Cn - switching o
ff
the compressor with the defective sensor (0 - 99 min.) - time when the compressor is switched o
ff
in case of the
defective thermostat sensor. In case of Cy = 0 setting, the compressor is always switched o
ff
.