9
GB
O R I G I N A L I N S T R U C T I O N S
PROPERTIES OF THE DEVICE
The industrial videoscope is a portable inspection device. It permits to see hardly accessible areas by means of a miniature cam-
era connected with a
fl
exible cable to a LCD colour screen whose diagonal is 89 or 61 mm. The camera of the device is equipped
with autonomous illumination based upon white LEDs, which permits to work even in total darkness.
COMPONENTS OF THE DEVICE
The device is provided complete and it does not require assembly. The package contains the following: videoscope with a camera,
power pack, wireless module, cable connecting the device with the wireless module, USB extension cable, software CD. Along
with the device are provided the following auxiliary terminals of the camera: with a hook, with a mirror and with a magnet.
TECHNICAL PARAMETERS
Parameter
Measurement unit
Value
Catalogue number
-
YT-7294
Power supply
[V]
3.7 d.c.
Type of battery
- lithium
polymer
Capacity of the battery (videoscope/screen)
[mAh]
1200
Charging time
[h]
~3.5
Diameter of the camera
[mm]
12.2
Visual
fi
eld of the camera
[
O
]
60
Focusing distance of the camera
[mm]
50
Camera lighting
-
2 x LED
Length of the camera conductor
[mm]
900
Working temperature
[
O
C]
10 - 45
Workplace relative humidity
[%]
5 - 95, without condensation
Maximum working time
[h]
2 - 3
Frequency of the wireless transmission (CH1; CH2; CH3; CH4)
[MHz]
2414; 2432; 2450; 2468
Wireless transmission range (max.)
[m]
10
Power pack
Input voltage
[V]
230 a.c.
Frequency of the input voltage
[Hz]
50
Output voltage
[V]
5,5 d.c.
Output current
[A]
1.5
Weight of the device (with the batteries)
[g]
530
Protection grade
IP20
SAFETY RECOMMENDATIONS
NOTE! Read carefully the following instructions before you commence work. Should the recommendations be not observed, there
is a risk of an electric shock,
fi
re or injuries.
The place of work must be properly lit and clean. Untidiness and poor lighting may be a cause of accidents.
Do not use the device in an explosive environment which contains in
fl
ammable liquids, gases or vapours.
Do not use the device in the vicinity of corrosive chemicals; they may impair the obtained picture.
Do not remove any labels from the device.
Do not permit children or unauthorised persons to the place where the device is being operated. A loss of concentration may lead
to a loss of control over the tool.
Always use personal protection means appropriate to the work being executed, such as protective glasses or goggles, gloves,
hearing and head protection, protective clothes and shoes.
Do not strive to reach anything, always maintain balance. A loss of balance may lead to an electric shock,
fi
re or injuries.
The device must be kept away from any liquids. The device is not hermetic and any contact with liquids may imply damage to the
tool and lead to an electric shock or injuries.
Do not use the device for the purposes related to investigation of human or animal organisms. The product has not been designed
for any medical applications.
The product is not shock-resistant. Do not place the device on unstable tables or other unstable surfaces, from which it might
fall. Do not drop anything on the device. Mechanical damage caused by failure to observe the safety recommendations are not
covered by the guarantee and may increase the risk of injuries.
The device should be stored in the unit package it is supplied in. The device should be stored in a dry, well ventilated place, away
from reach of children.