9
GB
O R I G I N A L I N S T R U C T I O N S
be replaced with a new one which is free of defects if these components are damaged. If
the plug has a ground contact, it must be connected to a power supply socket which is also
equipped with a ground contact.
Ozonation instructions
Warning! Do not stay indoors while the ozone generator is operating. During ozonation, leave
the room and return only 30-40 minutes after the ozone generator has
fi
nished its operation.
Do not use ozonation at high air temperature, above 40
o
C, in a heavily smoke-
fi
lled room or
with a high humidity. In such conditions, ozonation will not be e
ff
ective.
Avoid direct contact of hands and eyes with the ozone outlet.
If you experience discomfort, begin to cough, have a sore throat, a headache, feel drowsy
in contact with ozone, the ozone generator must then be switched o
ff
immediately and you
must move to a place with clean air, preferably to an open space, if possible.
In case of water ozonation, the appliance should be placed above the surface of water to be
ozonated.
Do not drink water immediately after ozonation. Wait 20-30 minutes after ozonation, then
fi
lter and boil the water. After cooling, the water should be drinkable.
Ioniser use instructions
Air ionisation changes the charge of particulates in the air from positive to negative. Ionisation
does not purify the air, but only facilitates the removal of particulates from the air. Ionisation
should be used with air ventilation and
fi
ltration to assist in air puri
fi
cation.
There must be a minimum of 1 metre distance between the appliance and other electrical
appliances if a negative ion generator is used.
There must be a minimum of 0.5 m distance between the appliance and electrical life support
equipment, e.g. pacemakers or arti
fi
cial organs.
Negative ions may interfere with the operation of other electrical equipment. If such inter-
ference is detected, switch o
ff
the appliances, increase the distance of the ioniser from the
appliances and try again.
APPLIANCE OPERATION
Preparing for operation
Unpack the appliance by removing all packaging components. Clean the external surfaces of the appliance according to the
instructions contained in the “Appliance maintenance” section. Set the appliance according to the instructions.
Plug the power cord plug into the socket on the front of the appliance. The socket and plug are made to
fi
t together so that it is
possible to connect in only one correct way.
Check that the appliance switch is in the “o
ff
” position – O, and the timer knob is in the “OFF” position.
Plug the power cord plug into the socket. The power supply network must be equipped with a protective conductor.
Switch the appliance on by moving the switch to the “on” position – I.
Start ozone generation by moving the timer knob to the “ON” position so that the generator operates continuously, or to a position
marked with a number. The numeric position indicates the number of minutes for which the appliance will generate ozone.
After the set time has elapsed, the appliance will automatically stop ozone generation. It is possible to set the time for up to 90
minutes.
The appliance can be switched o
ff
at any time by moving the switch to the “o
ff
” position - O.
Summary of Contents for YT-73350
Page 14: ...14 RUS 20 30...
Page 15: ...15 RUS 30 40 40 C 20 30 1 0 5...
Page 16: ...16 RUS O OFF I ON 90 O YT 73350 110 230 50 60 220 I 10 2 30 50 2 9 LwP 70...
Page 17: ...17 UA 20 30...
Page 18: ...18 UA 30 40 40 C 20 30 1 0 5...
Page 19: ...19 UA O OFF I ON 90 O YT 73350 110 230 50 60 220 I 10 2 30 50 2 9 LwP A 70...
Page 50: ...50 GR 20 cm 30cm...
Page 51: ...51 GR 30 40 40 C 20 30 1 0 5 m...
Page 52: ...52 GR O OFF ON 90 O YT 73350 V 110 230 Hz 50 60 W 220 I g h 10 m2 30 50 kg 2 9 LwP dB A 70...