background image

8

GB

O R I G I N A L   I N S T R U C T I O N S

PRODUCT OVERVIEW

The car compressor allows you to infl ate tyres and other items such 

as balls and mattresses with compressed air. The power supply from 

the vehicle’s electrical system allows for increased product mobility. 

The correct, reliable, and safe operation of the device depends on 

its proper use, so:

Reading and keeping the entire manual before the fi rst use of 

the device.

The supplier shall not be held liable for any damage resulting from 

failure  to  observe  the  safety  regulations  and  recommendations 

specifi ed in this manual.  

ACCESSORIES 

The product is supplied with a fl exible hose supplying compressed 

air to the item to be infl ated and with adapters to infl ate products 

other than vehicle tyres. 

SPECIFICATION

Parameter

Units

Value

Catalogue number

YT-73460

Rated voltage

[VDC]

12

Rated power

[W]

180

Maximum pressure

[MPa / bar]

1 / 10

Capacity

[l/min.]

40

Hose length

[m]

1,0

Power cord length

[m]

3,0

Weight

[kg]

1,8

SAFETY INSTRUCTIONS

CAUTION!  Read  all  of  the  following  instructions.  Failure  to  do  so 

may result in electric shock, fi re, or personal injury. 

FOLLOW THE INSTRUCTIONS BELOW

Do not use the product in an explosive environment containing fl am-

mable liquids, gases, or vapours. 

Do not place the device near any heat or fi re sources. 

Connect the device only to the power network with the voltage and 

frequency indicated on the nameplate of the device. 

The plug of the power cord must match the power socket. Do not 

modify the plug. Do not use any power adapters to adapt the plug to 

the socket. An unmodifi ed plug, which matches the socket, reduces 

the risk of an electric shock. 

After each application, unplug the power cord from the power socket. 

The device is intended for indoor use only. Do not expose the device 

to  any  precipitation  or  moisture.  If  water  and  moisture  enters  the 

device, the risk of electric shock is signifi cantly increased. Do not 

immerse the product in water or any other liquid. 

Do  not  obstruct  the  ventilation  openings  and  make  sure  they  are 

clear.  Obstructed  and/or  clogged  ventilation  openings  may  cause 

the device to overheat. This can lead to damage to the device or 

cause fi re or electric shock. 

Do not overload the power cord. Do not use the power cord to carry, 

connect, or disconnect the plug from the power socket. Avoid any 

contact between the power cord and heat sources, oil, sharp edges, 

and moving parts. Damage to the power cord increases the risk of 

electric shock. If the power cord is damaged (e.g. it is cut, its insula-

tion is melted), immediately unplug it from the wall socket, and return 

it to an authorised service facility. It is not allowed to use the product 

with a damaged power cord. It is not allowed to have the power cord 

repaired. It must be changed for a new one at an authorized ser-

vice centre. When using extension cords, use extension cords with 

power parameters such as those shown on the device’s nameplate. 

If you notice any damage to any part of the device, you must dis-

continue using it. In this case, the device must be taken to an au-

thorised service centre or replaced by yourself, if this is permitted by 

the user’s manual. 

Turn off  the device and unplug the power cord from the socket be-

fore you start any work on replacing parts, cleaning, or adjusting.  

Switch off  the device before replacing the accessories and unplug 

the power cord from the socket.  

This device may be used by children of at least 8 years of age and 

by persons with reduced physical, mental abilities and persons with 

no experience or knowledge of the device, if supervised or instructed 

on its safe use so that the risks associated with it were understanda-

ble. Children should not play with the device. Children should not be 

allowed to perform cleaning and maintenance of the product without 

supervision.

Warning! Never exceed the maximum pressure of the pumped 

products. Exceeding the maximum pressure can cause a sud-

den burst of the pumped product which can cause serious injury. 

If no maximum pressure is indicated on the product (e.g. mattress), 

check the hardness of the pumped product by pressing it with your 

hand. 

Never leave the product unattended during pumping.

The  compressor  is  designed  to  be  used  for  short  periods  of  time 

(maximum 10 minutes). Operation of the compressor for a long pe-

riod of time will cause overheating of the device and its damage.

Reduced performance or heating up of the area of the hose con-

nection to the casing means that the device has been running for 

too long and is overheating. When this happens, turn off  the device 

immediately and leave it for at least 30 minutes to cool down before 

restarting.    

Summary of Contents for YT-73460

Page 1: ...OMPRESSOR AUTO KOMPRESSOR AUTOMOBILINIS KOMPRESORIUS AUTO KOMPRESORS AUTOMOBILOV KOMPRESOR AUTOMOBILOV KOMPRESOR AUT KOMPRESSZOR COMPRESOR AUTO COMPRESOR DE COCHE COMPRESSEUR DE VOITURE COMPRESSORE D...

Page 2: ...zeczyta instrukcj Read the operating instruction Bedienungsanleitung durchgelesen i i Perskaityti instrukcij J lasa instrukciju P e tet n vod k pou it Pre ta n vod k obsluhe Olvasni utas t st Cite ti...

Page 3: ...jac k bel 5 hadica 6 zap na 7 adapt r 8 zap na lampy SK 1 kompresszor 2 manom ter 3 foganty 4 t pk bel 5 t ml 6 bekapcsol gomb 7 adapter 8 l mpa kapcsol H 1 kompresors 2 manometrs 3 rokturis 4 baro an...

Page 4: ...u tiem j b t v lreiz izlieto tiem p rstr d tiem vai dab tiem atpaka cit form OCHRANA IVOTN HO PROST ED Symbol poukazuje na nutnost separovan ho sb ru opot ebovan ch elektrick ch a elektro nick ch za z...

Page 5: ...r Verbruikte elektrische apparaten kunnen worden gerecycled Het is verboden dit bij het huishoudelijk afval te gooien aangezien dit sto en bevat die schadelijk kunnen zijn voor de gezondheid en voor h...

Page 6: ...ieczy Nie zas ania otwor w wentylacyjnych i dba o ich dro no Za s oni te i lub zatkane otwory wentylacyjne mog doprowadzi do przegrzania urz dzenia Mo e to doprowadzi do uszkodzenia urz dzenia a tak e...

Page 7: ...latora W cznik przestawi w pozycj w czony I lub ON kompresor roz pocznie pompowanie Aby sprawdzi ci nienie nale y zatrzyma pompowanie przesta wiaj c w cznik w pozycj wy czony O lub OFF a nast pnie od...

Page 8: ...use the power cord to carry connect or disconnect the plug from the power socket Avoid any contact between the power cord and heat sources oil sharp edges and moving parts Damage to the power cord inc...

Page 9: ...the pressure inside the pumped product When pumping is complete switch the compressor o disconnect the compressor from the power supply and then from the product being pumped Next proceed with mainte...

Page 10: ...nd Verdeckte und oder verstopfte L ftungs nungen k nnen zu einer berhitzung des Ger tes f hren Dies kann zu Sch den am Ger t zu Br nden oder Stromschl gen f hren Netzkabel nicht berlasten Stecker nich...

Page 11: ...beginnt zu pumpen Um den Druck zu berpr fen h ren Sie mit dem Pumpen auf indem Sie den Schalter in die Aus Stellung O oder OFF umschalten und lesen Sie dann das Manometer ab Schalten Sie den Kompresso...

Page 12: ...12 RUS YT 73460 DC 12 180 1 10 40 1 0 3 0 1 8 8...

Page 13: ...13 RUS 10 30 O OFF II III I ON O OFF IV 10 A 250 O I 0 40O C RH 85...

Page 14: ...14 UA YT 73460 12 180 1 10 40 1 0 3 0 1 8 8...

Page 15: ...15 UA 10 30 O OFF II III ON O OFF IV 10 250 O I 0 40 OC RH 85...

Page 16: ...ki tuko prijungimui arba atjungimui nuo maitinimo lizdo Vengti elek tros laido kontakto su iluma aliejumi a triais kra tais ir judan iomis dalimis Maitinimo kabelio pa eidimas padidina elektros oko ri...

Page 17: ...kt sl g Visuomet i junkite kompresori tam kad patikrintum te sl g gaminio viduje Po prip timo i junkite kompresori jungikliu atjunkite kompresori nuo maitinimo ir tada nuo pripu iamo produkto Tada pra...

Page 18: ...t baro anas kabeli Neizmantojiet baro anas kabeli ier ces p rne anai kontaktdak as piesl g anai kontaktligzdai un atsl g anai no t Izvairieties no baro anas kabe a saskares ar sil tumu e m as m mal m...

Page 19: ...as t spiedienu pump jam produkta iek pus P c pump anas beig m izsl dziet kompresoru ar sl dzi atvieno jiet kompresoru no str vas padeves p c tam no pump jam pro dukta P c tam veiciet apkopes darbus Sp...

Page 20: ...jec kabel k p en en p ipojen nebo odpojen nap jec z str ky ze z suvky Vyhn te se kontaktu nap jec ho kabelu s teplem oleji ostr mi hranami a po hybliv mi prvky Po kozen nap jec ho kabelu zvy uje rizik...

Page 21: ...dy vypnout kompresor abyste si p e etli hodnotu tlaku nafukovan ho produktu Po skon en nafukov n vypn te kompresor sp na em odpojte kom presor od nap jec ho zdroje a n sledn od nafukovan ho produktu N...

Page 22: ...jte ventila n otvory a prieduchy starajte sa aby boli v dy priepustn V opa nom pr pade tzn v pr pade zakrytia a alebo zapchatia prieduchov zariadenie sa m e prehria Zariadenie sa n sledkom toho m e po...

Page 23: ...ozna en symbolom pripojte ku kontaktu aku mul tora ktor je ozna en tak m ist m symbolom Prep na prepnite na zapnut polohu I alebo ON kompresor sa spust a za ne husti Ke chcete skontrolova tlak zastavt...

Page 24: ...Ne terhelje t l a t pk belt Ne haszn lja a t pk belt a term k t helyez s hez s a dug aljzatb l val kih z s hoz Ker lje hogy a t pk bel meleg fel lettel olajjal les t rggyal vagy mozg alkat r sszel ri...

Page 25: ...k nyom s nak elle n rz s hez a kompresszort mindig ki kell kapcsolni A pump l s v g n a kompresszort a kapcsol gomb seg ts g vel ki kell kapcsolni majd le kell csatlakoztatni a kompresszort az ramfor...

Page 26: ...ntare Nu folosi i cablul de alimentare pentru a transporta aparatul sau a deconecta techerul la sau de la priz Evita i contactul cablului de alimentare cu c ldura uleiurile mu chii ascu ite i piese n...

Page 27: ...ti i valoarea indicat de ma nometru Opri i ntotdeauna compresorul pentru a citi presiunea n obiectul um at C nd pomparea este nalizat opri i compresorul deconecta i com presorul de la sursa de aliment...

Page 28: ...s rejillas de ventilaci n obstruidas o tapadas pueden provocar el sobrecalentamiento de la unidad Esto puede provocar da os en la unidad un incendio o una descarga el ctrica No sobrecargue el cable de...

Page 29: ...compre sor comenzar a bombear Para comprobar la presi n detenga el bombeo moviendo el inte rruptor a la posici n de apagado O u OFF y luego lea el man me tro Siempre apague el compresor para leer la...

Page 30: ...n ferm es et ou obstru es peuvent provoquer une surchau e de l appareil Cela pourrait endom mager l appareil ou provoquer un incendie ou une lectrocution Ne pas surcharger m caniquement le cordon d al...

Page 31: ...identique Mettre l interrupteur en position marche I ou ON le compresseur commence pomper Pour v ri er la pression arr ter le pompage en mettant l interrupteur en position arr t O ou OFF puis lire l...

Page 32: ...aldamento dell apparecchio Ci pu causare danni all appa recchio o anche causare incendi oppure una scossa elettrica Non sovraccaricare il cavo di alimentazione Non utilizzare il cavo di alimentazione...

Page 33: ...r il gon aggio Per controllare la pressione arrestare il gon aggio portando l inter ruttore in posizione di spegnimento O o OFF quindi leggere il ma nometro Spegnere sempre il compressore per leggere...

Page 34: ...ektrische schokken veroorzaken Overbelast de voedingskabel niet Gebruik het netsnoer niet om de stekker uit het stopcontact te halen aan te sluiten of los te maken Vermijd contact van het netsnoer met...

Page 35: ...stopt u het pompen door de schakelaar in de uit stand O of OFF te zetten en leest u de manometer af Schakel de compressor altijd uit om de druk in het op te pompen product af te lezen Wanneer het pom...

Page 36: ...36 GR YT 73460 V d c 12 W 180 MPa bar 1 10 l min 40 m 1 0 m 3 0 kg 1 8 8...

Page 37: ...37 GR 10 30 O OFF I ON O OFF IV 10A 250V O I I 0 40 OC RH 85...

Page 38: ...I N S T R U K C J A O R Y G I N A L N A 38...

Page 39: ...I N S T R U K C J A O R Y G I N A L N A 39...

Page 40: ...I N S T R U K C J A O R Y G I N A L N A 40...

Reviews: