Installation of accessories
CAUTION! Only install the accessories when the supply voltage is disconnected. Pull the
tool power cord plug out of the power socket!
Before assembly and disassembly of the device, make sure that all components have
cooled down.
Before starting assembly, make sure that the soldering station power switch is in the o
ff
position – O.
If the tip has not been installed in the soldering iron, unscrew the front part of the soldering
iron, insert the tip (II) into it, and then screw it to the soldering iron.
Connect the soldering iron cable to the port at the front of the soldering station housing
(III). The plug has such a shape that it can be connected in one correct way only. Secure
the connection by screwing a metal plug ring on the thread around the port in the soldering
station housing.
Place the soldering iron in the stand (IV).
Connect the power cord to the port at the back of the housing. The plug has such a shape
that it can be connected in one correct way only.
Position the station at the workplace, e.g., on the table to ensure easy access to the con-
trols and that any object does not cover the display reading. Place the soldering iron stand
near the station to ensure free access to the soldering iron and prevent the soldering iron
tip from unintentional coming into contact with any object during operation, storage on the
stand, and movement of the soldering iron during operation. Due to the high temperature
of the tip, leave at least 10 cm of free space around the stand. The stand should be placed
on a heat-resistant surface.
Only after setting up the station and the stand and performing a trial operation can the
station be connected to the power supply.
Switching the device on and o
ff
Switch the device on by moving the power switch to the on position – I.
The display backlight switches on and after approx. 3 seconds the previous (factory) tem-
perature setting will be displayed.
If it is necessary to switch o
ff
the device, move the power switch to the o
ff
position – O.
Temperature setting
Place the soldering iron in the stand and switch on the station with the power switch. After
a few seconds, the display will show the current temperature.
Use the buttons marked with arrows to adjust the temperature. Pressing the arrow up but-
ton increases the temperature. Pressing the arrow down button decreases the tempera-
ture. The set temperature will be shown on display. Pressing the button once changes the
temperature by 1
O
C.
After the temperature is set, the indicator light in the lower right corner of the display will
light up; this means that the set temperature has been entered into the station memory.
Soldering tip temperature calibration
If the temperature of the tip is di
ff
erent than that shown on the display, calibrate the temperature.
Press and hold the setting button for 1-2 seconds to enter calibration mode, the display will
show “-00”. Use the arrow buttons to set the temperature di
ff
erence. If the temperature of
the tip is higher than the indication on the display, there must be a minus sign in front of the
di
ff
erence value. After entering the di
ff
erence between the temperature of the tip and the
display, press the setting button to exit the calibration mode
.
MAINTENANCE AND STORAGE
After
fi
nishing work, clean the tip using a damp sponge and then place the soldering iron
in the stand, switch o
ff
the soldering station with the power switch and leave it until all
elements have cooled down completely. Disconnect the station from the power supply by
pulling the power cord plug out of the power socket. Clean the station housing and soldering
iron holder with a soft cloth slightly dampened with water, then dry it.
Check the tip condition; if any defects, damage, or changes in shape are observed, replace
the tip with a new one. Unscrew the clamping sleeve by rotating the ring located near the
soldering iron handle. Then pull out of the sleeve the old tip and replace it with a new one.
Mount the sleeve with the tip to the soldering iron.
The sponge for cleaning the tip should be cleaned under a jet of lukewarm water. Replace
excessively soiled or damaged sponges with new ones.
Store the product disconnected from the power supply in places not accessible to unauthor-
ised persons, especially children. The storage place should protect against dust, moisture,
precipitation, excessive heat, and provide adequate ventilation to prevent condensation of
water vapour.
Summary of Contents for YT-82461
Page 13: ...13 RU I YT 82461 110 240 50 60 75 O C 90 480 O C 2 I 0 28 0O C 40O C 70 16...
Page 14: ...14 RU II III IV 10 I 3 O 1 C 1 2 00...
Page 15: ...15 RU...
Page 16: ...16 UA I YT 82461 110 240 50 60 75 O C 90 480 O C 2 I 0 28 0 O C 40 O C 70 16...
Page 17: ...17 UA O II III IV 10 I 3 O 1 1 2 00...
Page 18: ...18 UA...
Page 44: ...44 GR YT 82461 V 110 240 Hz 50 60 W 75 O C 90 480 O C 2 I kg 0 28 0 O C 40 O C 70 16 A...
Page 45: ...45 GR II III IV 10 cm I 3 O 1 O C 1 2 00...
Page 46: ...46 GR...
Page 47: ...47 GR...
Page 48: ...48 GR...