Device Manual
To set burst mode, in the Report Frequency you need to choose Burst. Then, in the Burst SeZngs
menu you can choose how ohen you wish to take a fix (Burst fix) and how ohen you wish to
transmit (Burst transmit).
Note: This mode will use power more quickly than other tracking modes, since GPS is kept on all of the
Fme.
Although airFme costs are reduced using burst mode, depending on your seZngs you may use more
than 1 credit per transmission. 1 credit will pay for up to 3 posiFons inside a single fix. So, for
example, if you are taking a posiFon every 5 minutes, and transmiZng every 15 minutes (so 3 fixes
transmi`ed), this will cost 1 credit per transmission. If you take a posiFon every 5 minutes, and
transmit every 30 minutes (so 6 fixes transmi`ed), this would cost 2 credits per transmission.
Ac9vity Sense
Turning acFvity sense ON will mean that the tracker will switch between the normal ‘report
frequency’ when staFonary, and transmiZng using the ‘burst seZngs’ when moving.
NOTE - THIS CAN COST SIGNIFICANT NUMBERS OF CREDITS, ONLY TURN THIS ON IF YOU
KNOW WHAT YOU ARE DOING!
AcFvity sense can be parFcularly useful if you want to transmit whilst you are moving, and then
transmit at a much slower rate when you are not moving. For instance, tracking vehicles or aircrah.
There are sensiFvity levels inside the AcFvity Sense menu which are useful to tweak when the
device thinks it is ‘moving’ - this will depend on your exact situaFon, but we have found that seZng
both opFons to ’24’ is a good start, and works for most situaFons.
Alert OpFons
Timer Alert
This opFon allows you to set an alert message to be sent aher a pre-defined interval. This is useful if
you would like to send an alert in the eventuality that you are not able to cancel the alert within a
pre-defined Fme. Timers can be chosen between 5-minutes to 12-hours.
Temperature Alert
Should the temperature leave your defined range (e.g. 0 degrees to 40 degrees) then an automaFc
alert will be sent. This opFon allows you to turn this alert type on/off and set the temperature over
which the alert will be sent.
Power Loss Alert
If this opFon is turned on, should the unit lose external power then an automaFc alert will be sent.
Geo-fence Alert
This alert type allows you to set your current posiFon, then set a distance. Should the device leave
the pre-defined circular area, an automaFc alert will be sent.
Collision Alert
6