Yealink SIP-T4X IP Phones Auto Provisioning Guide
58
If you want to reset the configuration of a parameter to factory setting, set the value of the
parameter to be !NULL! or %NULL%. For example, local_time.ntp_server1 = %NULL%. After the
auto provisioning process is completed, the NTP server 1 will be reset to “cn.pool.ntp.org”.
Parameter
Permitted
Values
Descriptions
Web Setting Path
network.ip_ad
dress_mode =
0, 1 or 2
It configures the IP address mode.
0-IPv4
1-IPv6
2-IPv4&IPv6
The default value is 0.
It takes effect after reboot.
Network->Internet
Port->Mode(IPv4/IP
v6)
network.intern
et_port.type =
0, 1 or 2
It configures the internet port type for
IPv4 when the IP address mode is
configured as IPv4 or IPv4&IPv6.
0-DHCP
1-PPPoE
2-Static IP Address
The default value is 0.
It takes effect after reboot.
Network->IPv4
Config
network.intern
et_port.ip =
IP address
It configures the IPv4 address when the
IP address mode is defined as IPv4 or
IPv4&IPv6, and the Internet (WAN) port
type for IPv4 is configured as Static IP
Address.
The default value is blank.
It takes effect after reboot.
Network->IPv4
Config->Static IP
Address->IP
Address
network.intern
et_port.mask
=
IP address
It configures the IPv4 subnet mask
when the IP address mode is defined
as IPv4 or IPv4&IPv6, and the Internet
(WAN) port type for IPv4 is configured
as Static IP Address.
The default value is blank.
It takes effect after reboot.
Network->IPv4
Config->Static IP
Address->Subnet
Mask
network.intern
et_port.gatew
IP address
It configures the IPv4 default gateway
when the IP address mode is
configured as IPv4 or IPv4&IPv6, and
Network->IPv4
Config->Static IP
Address->
Summary of Contents for SIP-T4X