Description
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold value
of MOS-LQ causes the phone to send a warning alert quality report to the central report collector.
For example, a configured value of 35 corresponds to the MOS score 3.5. When the MOS-LQ value com-
puted by the phone is less than or equal to 3.5, the phone will send a warning alert quality report to the
central report collector. When the MOS-LQ value computed by the phone is greater than 3.5, the phone
will not send a warning alert quality report to the central report collector.
If it is set to blank, warning alerts are not generated due to MOS-LQ.
Permitted
Values
15 to 40
Default
Blank
Web UI
Settings->Voice Monitoring->Warning threshold for Moslq
Parameter
phone_setting.vq_rtcpxr_moslq_threshold_critical
<y0000000000xx>.cfg
Description
It configures the threshold value of listening MOS score (MOS-LQ) multiplied by 10. The threshold value
of MOS-LQ causes the phone to send a critical alert quality report to the central report collector.
For example, a configured value of 28 corresponds to the MOS score 2.8. When the MOS-LQ value com-
puted by the phone is less than or equal to 2.8, the phone will send a critical alert quality report to the
central report collector. When the MOS-LQ value computed by the phone is greater than 2.8, the phone
will not send a critical alert quality report to the central report collector.
If it is set to blank, critical alerts are not generated due to MOS-LQ.
Permitted
Values
15 to 40
Default
Blank
Web UI
Settings->Voice Monitoring->Critical threshold for Moslq
Parameter
phone_setting.vq_rtcpxr_delay_threshold_warning
<y0000000000xx>.cfg
Description
It configures the threshold value of one-way delay (in milliseconds) that causes the phone to send a warn-
ing alert quality report to the central report collector.
For example, if it is set to 500, when the value of one way delay computed by the phone is greater than or
equal to 500, the phone will send a warning alert quality report to the central report collector; when the
value of one way delay computed by the phone is less than 500, the phone will not send a warning alert
quality report to the central report collector.
If it is set to blank, warning alerts are not generated due to one-way delay. One-way delay includes both
network delay and end system delay.
Permitted
Values
10 to 2000
Default
Blank
Web UI
Settings->Voice Monitoring->Warning threshold for Delay
Parameter
phone_setting.vq_rtcpxr_delay_threshold_critical
<y0000000000xx>.cfg
Description
It configures the threshold value of one-way delay (in milliseconds) that causes the phone to send a crit-
ical alert quality report to the central report collector.
For example, if it is set to 500, when the value of one-way delay computed by the phone is greater than or
equal to 500, the phone will send a critical alert quality report to the central report collector; when the
Summary of Contents for W60P Telesystem
Page 1: ......
Page 18: ...Table of Contents 11 Appendix 255 RFC and Internet Draft Support 255...
Page 19: ...Administrator s Guide for W60P W53P W41P DECT Phones 12...
Page 47: ...40 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 73: ...66 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 123: ...116 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 125: ...118 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 139: ...132 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 171: ...164 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 193: ...186 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 227: ...220 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 253: ...246 Administrator s Guide for W60P W53P W41P DECT Phones...
Page 261: ...254 Administrator s Guide for W60P W53P W41P DECT Phones...