Page 1: ...Hardware Installation Guide Yeastar K2 IPPBX Hardware Installation Guide Yeastar K2 IP PBX 1 0 December 4 2019 ...

Page 2: ...Contents Hardware Installation Guide 3 Installation Precautions Warning 3 Package List 3 Hardware Overview 4 Install Yeastar K2 IPPBX Rack Mount 6 ...

Page 3: ...be installed Avoid installation in direct sunlight too cold too hot or humid temperature range 0 C 40 C humidity range 60 or less Avoid installation in places where there is frequent vibration dust or contact with water and oil It is better to install an anti static floor Keep a distance from other devices and do not stack them with other devices Warning Do not disassemble or modify the device Nev...

Page 4: ...entification buttons are on the front and back panels When one of these buttons is pressed the LCD panel on the front and the system status indicator on the back flash until one of the buttons is pressed again Press the button to turn the system ID on and off If the system stops responding during POST press and hold the system ID button for more than five seconds to enter BIOS progress mode To res...

Page 5: ... error condition exists For example a failed fan PSU or a hard drive Hard drive indicator The indicator flashes amber if there is a hard drive error Electrical indicator The indicator flashes amber if the system experiences an electrical error for example voltage out of range or a failed power supply unit PSU or voltage regulator Temperature indicator The indicator flashes amber if the system expe...

Page 6: ...ntil one of the buttons is pressed again Press the button to turn the system ID on or off If the system stops responding during POST press and hold the system ID button for more than five seconds to enter BIOS progress mode To reset the iDRAC if not disabled in F2 iDRAC setup press and hold the button for more than 15 seconds 8 System identification connector Connects the optional system status in...

Page 7: ... end piece in the bottom and top holes of the first U 3 Engage the back end of the rail until it fully seats on the vertical rack flange Repeat these steps to position and seat the front end piece on the vertical flange 4 To remove the rails pull on the latch release button on the end piece midpoint and unseat each rail Step 3 Configure Flush Mount Static Rails Two or Four Post Note The rails must...

Page 8: ...mounting rails 2 Attach the fixed center mount brackets to the fron flanges with two pairs of screws 3 Slide both of the back brackets forward against t post rack and secure each side to the mounting flan screws Step 5 Configure Four Post Threaded Static Rails Note To configure your rails for a tooled installation you must perform step 3 and then perform the following steps for the back brackets 1...

Page 9: ...s lift the lock spring until it clears the pin and slide the chassis rails toward the front of the system until the pins can slip through the keyhole slots Step 8 Install the System in the Rack 1 Insert the ends of the chassis rails into the front of the rails mounted to the rack and push the system into the rack 2 Depending on the rail configuration the latches on the front of the system engage a...

Page 10: ...se the dedicated power cable Failure or damage caused by using other power cables is not covered by the warranty 1 Connect the Ethernet cable between Gb1 network port on the device and the LAN port on the switch 2 Connect a dedicated power cable to the device to power on The power indicator solid green after startup ...