Figure 2-3 MyPBX U300 Rear Panel 

 

 

LED 

Indication 

Status 

Description 

Power 

Power status 

On 

The power is switched on 

Off 

The power is switched off 

RUN 

MyPBX status 

Blinking 

MyPBX is running properly 

Not Blinking/Off 

MyPBX goes wrong 

 

Ports 

Description 

RJ11 ports 

FXS port

: For the connection of analog phones.   

Ethernet ports 

MyPBX  U300  provides  two  10/100M  adaptive  RJ45  Ethernet  ports,  marked  as  LAN  and 
WAN.   
-

LAN port

: LAN port is for the connection to Local Area Network (LAN).   

-

WAN port

: WAN port is the network port for the connection to internet. It supports ‘DHCP 

server’, ‘PPPoE/dynamic DNS’, and “static IP” for IP address assignment. 

E1/T1 ports 

For the connection to E1 line or the E1 port of traditional PBX.   

Audio 

Input 

port 

For the connection to a music-on-hold source 

Audio  output 
port 

For the connection to a paging system. 

Reset Button 

Press the reset button to restore the factory defaults 

Please  make  sure  that  you

d  like  to  reset  because  once  reset,  the  previous 

configurations would be erased automatically. 

Power port 

For the connection of a power adapter to input 100~240V

50~60HZ AC power         

USB port   

 

Console port 

For debugging 

 

2.3 Specifications and Operating Environment   

 

Description 

Size 

L213 * W 160 * H 44 (mm)

 

Power Supply 

220V,50

60Hz 

Summary of Contents for MyPBX U300

Page 1: ...MyPBX U300 Installation Guide http www yeastar com 1 13 MyPBX U300 Installation Guide Version V1 0 Yeastar Technology Co Ltd Date 25th July 2012 ...

Page 2: ...ctions 6 3 2 Installation instructions 6 3 2 1 Connection of ethernet ports 6 3 2 2 Connection of E1 T1 ports 7 3 2 3 Connection of FXS ports 8 3 2 4 Power connection 9 3 2 5 Overall flow chart 9 4 Mypbx u300 basic configurations 9 4 1 Factory defaults 9 4 2 Logging in the web configuration panel 10 4 3 Network settings 11 4 4 Extensions and setup management 11 4 5 Configuring terminals 11 4 6 Mak...

Page 3: ...PBX U300 Because they are able to select their local language for Web GUI and Voice Prompt Furthermore it is renowned for its user friendly web configuration panel which is easy accessible and self evident making configuration a trouble free job This Guide explains how to install MyPBX U300 how to configure MyPBX U300 via web interface how to add extensions and make receive calls via PSTN lines 1 ...

Page 4: ...MyPBX U300 Installation Guide http www yeastar com 4 13 2 Hardware Specifications 2 1 Overview Figure 2 1 MyPBX U300 2 2 LED Indicators and Ports Figure 2 2 MyPBX U300 Front Panel ...

Page 5: ...t is the network port for the connection to internet It supports DHCP server PPPoE dynamic DNS and static IP for IP address assignment E1 T1 ports For the connection to E1 line or the E1 port of traditional PBX Audio Input port For the connection to a music on hold source Audio output port For the connection to a paging system Reset Button Press the reset button to restore the factory defaults Ple...

Page 6: ...transmitters and high frequency and high current devices Is using independent power junction box and effective anti grid interference measures have been taken Mechanical load Please make sure that the device is placed steadily to avoid any accident that might cause damage If placed on the desktop please ensure it is horizontally placed 3 2 Installation Instructions After placing MyPBX U300 in a su...

Page 7: ...the line sequence of E1 port From the above table we can see that the No 1 and No 2 pins of MyPBX U300 E1 port is for receiving data No 1 for receiving data No 2 for receiving data while No 4 and No 5 is for transmitting data No 4 is for transmitting data No 5 is for transmitting data When connected to the E1 line RX of E1 port should be connected to TX of E1 line RX of E1 port should be connected...

Page 8: ...p www yeastar com 8 13 Figure 3 2 Connection of E1 T1 port 3 2 3 Connection of FXS ports The FXS port could be connected to an analog phone with a phone line The connection could be depicted as below Figure 3 3 Connection of FXS ports ...

Page 9: ...WER and RUN indicator lights would turn on Please switch off the power before plugging or unplugging the cables 3 2 5 Overall Flow Chart Figure 3 4 Overall Flow Chart 4 MyPBX U300 Basic Configurations 4 1 Factory Defaults MyPBX U300 provides web based configuration interface for administrator and account user The user can manage the device by log in the web interface The factory default IP address...

Page 10: ... can be connected when commit Ping MyPBX IP address command Start the browser on PC In the address bar enter the IP address click enter button and then you can see MyPBX U300 Web Configuration Panel login page See Figure 4 1 Figure 4 1 MyPBX Web Configuration Panel Login Page Enter the Admin User Name and Password to log in Figure 4 2 MyPBX Admin Configuration Interface Via the configuration inter...

Page 11: ... IP address subnet mask default gateway DNS etc 3 If MyPBX is connected to ADSL adapter directly please select PPPoE option and enter the ADSL user name and password LAN Settings Click Network Settings LAN Settings on the left menu bar of the web configuration interface LAN port is used for the interoperability of IP terminals and MyPBX If the LAN port is connected to the company s LAN please conf...

Page 12: ...er s extension number 2 Outbound calls Firstly please connect a PSTN line to the first FXO port Then the default extensions are able to make outbound calls via this trunk by simply dialing 9 phone number The is Key as Send Note The dial pattern of the default outbound route is 9 But if the user has changed it please dial the new prefix instead of the digit 9 when making outbound calls 3 Inbound ca...

Page 13: ...ide only explains the installation and basic settings of MyPBX U300 for making and receiving calls For more functionality and advanced settings of MyPBX U300 please refer to the relative documents as below MyPBX U300 Datasheet MyPBX U300 Administrator s Guide MyPBX U300 User s Guide The End ...

Reviews: