background image

 

   

NeoGate TA Series Installation Guide 

 

                

 

10/20 

 

LED 

Indication 

Status 

Description 

POWER  Power status 

On 

The power is switched on. 

Off 

The power is switched off. 

RUN 

NeoGate status 

Blinking 

NeoGate is running properly. 

Not Blinking/Off  NeoGate goes wrong. 

1-32 

FXS Ports 
Status 

Green light

 

Solid green: the port is idle. 
Green light blinking: there is an ongoing call on 
the port. 

1-8 

FXO Ports 
Status 

Table 2-1 LED Indications 

 

Ports 

Description 

Ethernet Port 

NeoGate provides 1 10/100 adaptive RJ45 Ethernet ports, marked as LAN. 
-

LAN port

: LAN port is for the connection to Local Area Network (LAN). 

Reset Button 

Press the reset button to restore the factory defaults. 

Please make sure that you want to reset, because once reset the previous 

configurations would be erased automatically. 

Power Inlet 

For connection of power supply. 

RJ11 FXS Ports 

For connection of analog phones/fax machines. 

RJ11 FXO Ports 

For connection of PSTN interfaces or PBX extension interfaces. 

RJ21 FXS Ports 

For connection of analog phones/fax machines with an RJ21 to RJ11 cable. 

RS232 Console Port 
(TA1600/1610/2400/3200) 

For debugging. 

Table 2-2 Ports Descriptions

 

2.3 Specifications and Operating Environment   

TA400/410/800/810 

Description 

Size (L×W×H) 

200 mm × 137 mm × 25 mm

 

Power Supply 

12V 1A

 

Operating Temperature 

0 to 40°C, 32 to 104°F 

Storage Temperature 

-20

 to 

65°C, 4

 to 

149°F 

Humidity 

10%~90% 

(

Non-condensing) 

Table 2-3 NeoGate TA400/410/800/810 Specifications and Operating Environment 

 

TA1600/1610/2400/3200 

Description 

Size (L×W×H) 

440 mm × 250 mm × 44 mm 

Power Supply 

AC 100-240V 50/60Hz 

Operating Temperature 

0 to 40°C, 32 to 104°F 

Storage Temperature 

-20 to 65°C, 4 to 149°F 

Humidity 

10% to 90% 

(

non-condensing) 

Table 2-4 NeoGate TA1600/1610/2400/3200 Specifications and Operating Environment

 

Summary of Contents for NeoGate TA400

Page 1: ...NeoGate TA Series Installation Guide Version 1 2 Date April 1 2015 Yeastar Information Technology Co Ltd...

Page 2: ...nstructions 12 3 2 Installation Instructions 12 3 2 1 Wall mount Instruction 12 3 2 2 Connection of Ethernet Ports 13 3 2 3 Connection of FXS Ports 14 3 2 4 Connection of FXO Ports 14 3 2 5 Power Conn...

Page 3: ...eparation before Installation Please make sure the following devices are available before installation Contents of the box Upon receiving NeoGate gift box please open the package and check if all the...

Page 4: ...Gate TA Series Installation Guide 4 20 Mounting ears PC 2 Screws PC 8 8 screws 3 0 6 mm for mounting ears Grounding stud and nut Pair 1 Rubber feet PC 4 Sheet 2 NeoGate TA1600 1610 2400 3200 Packing L...

Page 5: ...erview Figure 2 1 NeoGate TA Series Analog VoIP Gateways Models Telephony Interfaces RJ11 FXS Ports RJ11 FXO Ports RJ21 FXS Ports NeoGate TA400 4 NeoGate TA410 4 NeoGate TA800 8 NeoGate TA810 8 NeoGat...

Page 6: ...NeoGate TA Series Installation Guide 6 20 Figure 2 2 NeoGate TA Telephony Interfaces...

Page 7: ...milar the difference is the number for ports and the type of ports Take the front panel and rear panel of NeoGate TA800 and NeoGate TA3200 as examples Front Panels Figure 2 3 NeoGate TA800 Front Panel...

Page 8: ...n Guide 8 20 Rear Panels Figure 2 5 NeoGate TA800 Rear Panel Protective Earth RJ21 FXS Ports RUN CONSOLE Power Switch Power Inlet RESET POWER LAN Port Power Inlet RESET LAN Port WAN Port reserved FXS...

Page 9: ...NeoGate TA Series Installation Guide 9 20 Figure 2 6 NeoGate TA3200 Rear Panel...

Page 10: ...ower Inlet For connection of power supply RJ11 FXS Ports For connection of analog phones fax machines RJ11 FXO Ports For connection of PSTN interfaces or PBX extension interfaces RJ21 FXS Ports For co...

Page 11: ...NeoGate TA Series Installation Guide 11 20...

Page 12: ...om high power radio radar transmitters and high frequency and high current devices Is using independent power junction box and effective anti grid interference measures have been taken Mechanical load...

Page 13: ...o the wall 3 2 2 Connection of Ethernet Ports NeoGate TA provides one 10 100M adaptive RJ45 Ethernet LAN port LAN Port Connection Connect one end of a network cable to the LAN port of the Gateway and...

Page 14: ...n of FXO Ports NeoGate TA FXO Gateways include TA410 TA810 and TA1610 supporting 4 8 and 16 FXO ports respectively Connect the FXO interfaces to the Public Telephone Network PSTN or a PBX extension in...

Page 15: ...NeoGate TA Series Installation Guide 15 20 Figure 3 2 NeoGate TA810 Connection Diagram...

Page 16: ...NeoGate TA Series Installation Guide 16 20 Figure 3 3 NeoGate TA3200 Connection Diagram...

Page 17: ...and DNS address by default Please enable DHCP Server in your network to obtain the IP address Due to the difference of telephony interface NeoGate TA FXS Gateway and FXO Gateway will use different me...

Page 18: ...Web Configuration Panel Start the browser on PC In the address bar enter the IP address click Enter button and then you can see NeoGate Web Configuration Panel login page Figure 4 2 NeoGate TA Web Co...

Page 19: ...is used for the interoperability of IP terminals and NeoGate If the LAN port is connected to the company s LAN please configure the correct IP address and corresponding subnet mask Please note that af...

Page 20: ...s to reset During the process please do not power off until the RUN indicator become normal which means the reset process is completed Note After resetting all the configurations made by the admin wou...

Reviews: