background image

                                                   

   

                                                     

 

 

www.

yeeka

co

.com

 

 

15 

(two-factor authentication)

  

Delete all users

 

 

Long press 1 Programming Password # 21 #

 

This operation deletes all users card and password.

 

Change 

Programming 

Password

 

 

Long press 1 Programming Password #90 New 

Programming Password #

   

The programming password is 6 digits. If users forget 

the  programming  password,  they  can  long  press  the 

reset button to restore the factory settings.

 

3.6.2              Card read programming 

3.6.2.1          Card read programming(when the handle has keypad) 

Programming 

name

 

Programming content

 

Note

 

Add user card

 

 

Long  press  1  Programming  Password  #14  read  the 

card #

  

If users need to add more than one user cards at a 

time, they can read the card continuously.

 

Delete user card

 

 

Long  press  1  Programming  Password  #15  read  the 

card #

 

If users need to delete multiple user cards at a time, 

they can read the card continuously.

 

 

 

 

3.6.2.2          Card read programming(when the handle has no keypad) 

Restore factory 

settings

 

Long press “reset” button for 5 seconds

 

The programming password is restored to 123456, 

and the user information is cleared.

 

Add administrator 

card 

(when the handle 

has no keypad)

 

After leaving the factory, users shortly press the “fingerprint 

or card setting” button and then read a card.   

The first card read is the administrator card.

 

(Only one administrator card can be set, and normal 

user  cards  can  be  added  by  pressing  keypad  and 

administrator  cards.)  Clearing  administrator  card   

requires factory reset.

  

Add user card 

(when the handle 

has no keypad)

 

Read the administrator card → shortly press “fingerprint or 

card setting” button and read a new blank card

 

Add one card at a time

 

Delete user card 

(when the handle 

has no keypad)

 

Read the administrator card → long press “fingerprint or 

card setting” button and read the authorized card

 

Delete one card at a time

 

 

3.6.3              Fingerprint setting 

 

Add finger print

 

Shortly press the “fingerprint setting” button and then put 

your fingerprint in the authentication area for 

authentication

 

Release  the  fingerprint  once  after  pressing  for  two 

seconds.  The  beep  indicates  that  the  fingerprint 

needs  to  be  further  authenticated.The  successful 

beep indicate that the authentication is successful.

 

 

Summary of Contents for 1507 IoT Lock

Page 1: ...07 IoT Lock Operation Manual V1 0 0 Wenzhou Yeeka Lock Technology Co Ltd Address No 49 Fuyang North Road Sanxi Industrial Park Ouhai district Wenzhou China Tel 86 577 89609068 Mobile 86 13588925107 E mail info yeekaco com ...

Page 2: ...roduct appearance 8 3 2 Installation Diagram 9 3 3 Wiring Diagram 10 3 4 Functional schematic diagram 10 3 4 1 Password functional schematic diagram 10 3 4 2 Card read functional schematic diagram 11 3 4 3 Finger print functional schematic diagram 11 3 4 4 Lock back functional schematic diagram 12 3 4 5 Head functional schematic diagram 12 3 5 Operation Instructions 13 3 5 1 Access way of Mechanic...

Page 3: ...amming instructions 14 3 6 1 Password programming 14 3 6 2 Card read programming 15 3 6 2 1 Card read programming when the handle has keypad 15 3 6 2 2 Card read programming when the handle has no keypad 15 3 6 3 Fingerprint setting 15 4 Controller instructions 16 4 1 Functional diagram 16 4 2 Wiring diagram 16 4 3 Operating instructions 17 4 3 1 Controller configuration 17 4 3 2 Platform operatio...

Page 4: ...for product support All 1507 IoT lock have a serial name which is a unique identifier used to track the history of manufacturing sales and maintenance The serial name is located on the back of the device in the following format SN 167777777 The service provider of Yeeka products also provides technical support and services If yeeka or a certified service provider provides extended warranty or othe...

Page 5: ...unctions such as diversified access ways user authority management query of lock operation records and intelligent management of lock tasks 2 Adopt modular design no special control unit and readers integrated with password button card readers Bluetooth communication modules fingerprint identification modules RS485 communication modules 3 Driven by high reliability motor and adopted high stability...

Page 6: ...www yeekaco com 6 Access Unit Management Platform Switch Access Unit Access Unit Wireless Wireless electronic lock Wired electronic lock Sensor 2 2 System Architecture Diagram ...

Page 7: ...humidity Data analysis of other sensors 2 3 Management Platform Features Monitor Center Equipment information overview Display lock status by color change Real time alarm alerts Powerful search query function to get rapid positioning of the lock Equipment Management Set the lock area Manage lock and control unit User Management User authority management User department management ...

Page 8: ...www yeekaco com 8 3 IoT Lock instructions 3 1 Product appearance ...

Page 9: ...www yeekaco com 9 Screw Panel Mounting bracket Cam Locating plate Lock 3 2 Installation Diagram ...

Page 10: ...Pin No Color Signal Definition Wire Gauge 1 Red 12V UL2464 26AWG 2 Black GND 3 Yellow 485 4 Green 485 5 White DO 6 Blue DO 7 Orange lock status 8 Brown lock status 3 4 Functional schematic diagram 3 4 1 Password functional schematic diagram ...

Page 11: ...www yeekaco com 1 1 3 4 2 Card read functional schematic diagram 3 4 3 Finger print functional schematic diagram ...

Page 12: ...lled by force Reset button Long press for three seconds to restore the factory settings Setting button for fingerprint or card Bar code Contains lock hardware information Back 3 4 5 Head functional schematic diagram External power interface Interface type type c Used for emergency power supply unlock ...

Page 13: ...When green of the lock status LED keeps on then you can lift the handle and open the lock For the setting of password authority please refer to Programming instructions 3 5 5 Access way of card read Read the authorized IC card in the area of card read at this moment the lock status LED turns from blue to green with blink and the buzzer sounds three times When green of the lock status LED keeps on ...

Page 14: ...y with sound prompt 2 Entering Programming Password with sound prompt 3 6 1 Password programming Programming name Programming content Note Add user password Long press 1 Programming Password 12 new password User password is 6 digits The user can set multiple sets of passwords for unlocking When users unlock through password enter the password and press to unlock Delete user password Long press 1 P...

Page 15: ...ogramming password is restored to 123456 and the user information is cleared Add administrator card when the handle has no keypad After leaving the factory users shortly press the fingerprint or card setting button and then read a card The first card read is the administrator card Only one administrator card can be set and normal user cards can be added by pressing keypad and administrator cards C...

Page 16: ...troller instructions 4 1 Functional diagram 4 2 Wiring diagram Connect with IoT lock Connect with door sensor Program upgrade port Button to set lock Indicator light Ethernet interface Power Interface Reserved antenna position ...

Page 17: ...Lock C1 L3 corresponds to C1 Controller s L3 port Lock C1 L4 corresponds to C1 Controller s L4 port Remark The meaning of C1 L1 Lock corresponds to C1 Controller s L1 port Access unit indicator light Red The network is not connected Blue During the network configuration waiting about 10 20 seconds which depending on the network conditions Green The network connection is successful the server conne...

Page 18: ...uency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try t...

Reviews: