background image

Yellow Diving heating system manual 

 
 

 

6.  Place the cable in a desired direction inside the dry-suit. 
7.  Place internal cap and click it into place. 
 

THROU

 – to mount dry-suit connector please follow: 

 

 

 
1.  Punch a hole 9 mm in diameter in a chosen place of dry suit. 
2.  From outside of dry-suit paste a rubber pad, from inside paste connectors 

container, fit the openings on both parts. 

3.  Use a glue intended to use with rubber, i.e. TIPTOP CEMENT SC4000 with 

TIPTOP  E-40  hardener.  All  surfaces  should  be  tarnished  and  degreased, 
use only a thin, even layer of glue. 

4.  Pass  connectors  through  a  hole  in  dry  suit,  place  the  pad  and  secure 

screwing the nut. 

5.  Connect cables inside the container. 
6.  Screw the container cover. 
7.  Leave the suit for drying according to the directions for a glue used. 
 

 

Battery packs canisters 

The are two canister series for Yellow Diving heating systems: 
 

 

 

 

 

   

 

    H                                             PERCH H 

 

• 

H

 – Battery canister series with battery packs capacity from 10,4Ah to 

40,8Ah, with toggle switch shielded with rubber

 

• 

PERCH H

 – battery canister series with battery packs capacity from 

10,4Ah to 40,8Ah with solid metal press switch 

 

 
 
Canisters  are  manufactured  from  a  single  Delrin  rod,  lightweight 
but  resistant  material,  with  great  insulation  capabilities.  This 
material  is  perfect  for  diving  in  any  environment.  Watertight  E/O 
cord  is  disconnectable  under  water.  Battery  pack  is  double  sealed 
to  avoid  flooding,  even  when  canister  lid  is  not  properly  closed. 
Canister  latches  are  stainless  steel  with  secure  pads.  Possibility  of 
accidental opening is elliminated. Battery packs are delivered fully charged.  

Summary of Contents for THERMOV

Page 1: ...MANUAL and MAINTENANCE DIRECTIONS Yellow Diving Heating System ...

Page 2: ...ty Card either If you still have questions after reading this manual please contact e mail yellowdiving eu gmail com Yellow Diving Artur Okoniewski ul 11 Płk Piechoty 30 78 500 Drawsko Pomorskie Poland yellowdiving eu gmail com www yellowdiving eu Contents General informations 3 Dry suit connectors 3 Battery packs canisters 4 Heating vest 5 Heating gloves 5 Warnings 6 Pre dive procedure 7 When div...

Page 3: ...ector mounted in a hole punctured in dry suit layer Connector mount THERMOV Follow these steps to mount integrated inlet valve 1 Unscrew original dry suit inlet valve 2 Place THERMOV inside dry suit s sealing for inlet valve 3 Rotating THERMOV please set the direction of E O connector 4 Secure the valve with the enclosed nut screwing it with a groove upwards Connect valve connectors to the cable s...

Page 4: ...he container cover 7 Leave the suit for drying according to the directions for a glue used Battery packs canisters The are two canister series for Yellow Diving heating systems H PERCH H H Battery canister series with battery packs capacity from 10 4Ah to 40 8Ah with toggle switch shielded with rubber PERCH H battery canister series with battery packs capacity from 10 4Ah to 40 8Ah with solid meta...

Page 5: ...o active underwear to keep sweat out of the body Thin layer of fabric neither constrains diver body movements nor creates an air trap Contiguous in shape does not need high temperatures to heat diver body the whole system is energy saving what effects in longer burn times Heating vest is manufactured from material limiting formation and retention of unpleasing odours after usage Hand washing is po...

Page 6: ... use automatic dryers Warnings 1 Not complying to manual directions could cause personal injury and damage of the heating system 2 Always check heating system before dive 3 When planning the dive always make assumption that heating could fail In any circumstances do not use any other power sources that Yellow Diving battery packs This can result in burns and damaging the heating system 4 Do not ca...

Page 7: ...mean half power Only heating vest is designed for power regulation Heating gloves are always full power when on regarding current vest heating power Switching off and again on makes power regulation change from half to full power in a flip flop sequence 12 Switch the power regulator into half power three beeps and keep heating for at least one minute heating test Temperature increase during the te...

Page 8: ...ing The warranty on Light and Heating modules relates to their performance with the exception of the battery packages cables connectors E O light bulbs electronics heating gloves rubber hood switch for which the warranty period is 12 months from a date of purchase 2 Floods leaks punctures and broken bulbs etc are not covered by the warranty unless they are the direct result of a material or workma...

Page 9: ...stem manual 9 Warranty Card Serial number Serial number Serial number Date of purchase Stamp and signature of the producer Stamp and signature of the dealer Warranty and after warranty service record Date Description Signature ...