8.  Remember  –  after  one  year  from  purchase  claim  for  manufacturer’s 

service.  Toggle  switch  rubber  hood  should  be  exchanged  every year (this 
is paid service). 

Pre-dive procedure 

1.  Check if battery is charged. 
2.  Check to make sure, that E/O cord or toggle switch (H series only) rubber 

hood do not suffer from cuts or other damages. 

3.  Make sure, that canister cover o-ring is present and in-place. There are no 

reasons to remove the o-ring when store. Check the canister cover and o-
ring  and  remove  dirt  and  sand.  Do  not  grease  the  o-ring,  dirt  and  sand 
stick to greased surfaces. 

4.  Place  the  cover  over  the  canister  to  insert  banana  connectors  into  the 

sockets.  Slide  the  cover  down,  until  o-ring  reaches  the  canister.  Never 
latch the cover using excessive force. 

5.  Check the function of the latches. 
6.  When closing the latches, make it lock evenly and simultaneously. Check if 

securing pads are locked. 

7.  Put on the heating vest and heating gloves. 
8.  Connect battery pack into dry-suit connector, and connect the heating vest 

and heating gloves to dry-suit cable. 

9.  After  switching  on  a  beeping  sound  from  the  power  regulator  should  be 

heard (one or three beeps). 

10.Take care to identify the beeping sounds. 
11.There  are  two  steps  of  power  regulation.  Single  beep  means  full  power, 

three  beeps  mean  half-power.  Only  heating  vest  is  designed  for  power 
regulation.  Heating  gloves  are  always  full  power  when  on,  regarding 
current  vest  heating  power.  Switching  off  and  again  on  makes  power 
regulation change from half to full power in a flip-flop sequence.  

12.Switch the power regulator into half-power (three beeps) and keep heating 

for  at  least  one  minute  (heating  test).  Temperature  increase  during  the 
test  should  not  rise  above  thermal  comfort.  If  does  not,  heating  is  ready 
for a dive.  

13.If  temperature  increases  above  your  acceptable  comfort  level  during  one 

minute  heating  test,  switch  off  heating  and  do  not  use  on  the  dive.  If 
beeping sound could not be heard after switch-on, check the connections. 

14.After  heating  test  switch  off  the  heating,  but  remember,  the  nearest 

switch-on is full-power. 

When diving 

1.  At  the  very  beginning  (first  minute)  switch  on  the  heating.  According  to 

the  pre-dive  procedure,  it  should  be  full-power.  If  you  feel  temperature 
increase,  it  means  that  all  connections  are  working  good.  You  can  switch 
off the heating. 

2.  Next  switch  on  results  in  half-power  mode.  Every  switch  off  and  then 

switch on sequence changes the power mode. 

3.  Switching on the heating is advised before first symptoms of hypothermia 

occur. 

4.  Adjust the heating power to your needs – achieve thermal comfort. 
5.  Remember,  thermal  comfort  under  water  is  different  experience  than  on 

the surface. Work load has a large influence on thermal comfort. 

6. 

Do not overheat. In can result in increased risk of decompression sickness.

 

  

Summary of Contents for THERMOV

Page 1: ...MANUAL and MAINTENANCE DIRECTIONS Yellow Diving Heating System ...

Page 2: ...ty Card either If you still have questions after reading this manual please contact e mail yellowdiving eu gmail com Yellow Diving Artur Okoniewski ul 11 Płk Piechoty 30 78 500 Drawsko Pomorskie Poland yellowdiving eu gmail com www yellowdiving eu Contents General informations 3 Dry suit connectors 3 Battery packs canisters 4 Heating vest 5 Heating gloves 5 Warnings 6 Pre dive procedure 7 When div...

Page 3: ...ector mounted in a hole punctured in dry suit layer Connector mount THERMOV Follow these steps to mount integrated inlet valve 1 Unscrew original dry suit inlet valve 2 Place THERMOV inside dry suit s sealing for inlet valve 3 Rotating THERMOV please set the direction of E O connector 4 Secure the valve with the enclosed nut screwing it with a groove upwards Connect valve connectors to the cable s...

Page 4: ...he container cover 7 Leave the suit for drying according to the directions for a glue used Battery packs canisters The are two canister series for Yellow Diving heating systems H PERCH H H Battery canister series with battery packs capacity from 10 4Ah to 40 8Ah with toggle switch shielded with rubber PERCH H battery canister series with battery packs capacity from 10 4Ah to 40 8Ah with solid meta...

Page 5: ...o active underwear to keep sweat out of the body Thin layer of fabric neither constrains diver body movements nor creates an air trap Contiguous in shape does not need high temperatures to heat diver body the whole system is energy saving what effects in longer burn times Heating vest is manufactured from material limiting formation and retention of unpleasing odours after usage Hand washing is po...

Page 6: ... use automatic dryers Warnings 1 Not complying to manual directions could cause personal injury and damage of the heating system 2 Always check heating system before dive 3 When planning the dive always make assumption that heating could fail In any circumstances do not use any other power sources that Yellow Diving battery packs This can result in burns and damaging the heating system 4 Do not ca...

Page 7: ...mean half power Only heating vest is designed for power regulation Heating gloves are always full power when on regarding current vest heating power Switching off and again on makes power regulation change from half to full power in a flip flop sequence 12 Switch the power regulator into half power three beeps and keep heating for at least one minute heating test Temperature increase during the te...

Page 8: ...ing The warranty on Light and Heating modules relates to their performance with the exception of the battery packages cables connectors E O light bulbs electronics heating gloves rubber hood switch for which the warranty period is 12 months from a date of purchase 2 Floods leaks punctures and broken bulbs etc are not covered by the warranty unless they are the direct result of a material or workma...

Page 9: ...stem manual 9 Warranty Card Serial number Serial number Serial number Date of purchase Stamp and signature of the producer Stamp and signature of the dealer Warranty and after warranty service record Date Description Signature ...

Reviews: