Perform the following steps to turn the Tank Capacity Mode Off: 
1.  While holding the “ZERO” key down, press the “SET” key. The 

SET TANK 

indicator will turn on, and ON will show on the display. This indicates that the 
Tank Capacity Mode is currently on. 

2.  Turn the Tank Capacity Mode off by pressing the “DOWN” key. The display 

will show 

OFF

, and the Alternate Numeric Display will turn off. 

3.  Press the “RUN/STOP” key to return to normal operation. 

 

 

Turning the Tank Capacity Mode On without Re-training 
The Tank Capacity Mode can be turned back on without retraining. The 68860 will 
remember the previous 0% and 100% set points until the unit is re-trained as above.  
To turn the Tank Capacity Mode on without re-training, perform the following steps: 
1.  While holding the “ZERO” key down, press the “SET” key. The 

SET TANK 

indicator will turn on, and 

OFF

 will show on the display. This indicates that the 

Tank Capacity Mode is currently off. 

2.  Turn the Tank Capacity Mode on by pressing the “UP” key . The display will 

show 

ON

, and the Alternate Numeric Display and Percent Indicator will turn on. 

3.  Press the “RUN/STOP” key to return to normal operation. 
 

 

Because of its high stability and accuracy, the 68860 is ideal for automotive, commer-
cial, and residential A/C refrigerant charging and recovery. Its high resolution also 
allows accurate critical charging of small refrigeration systems such as commercial 
freezers. To use the 68860 for refrigerant charging, perform the following steps: 
1.  Press the “UNITS” key to set the desired display units. 
2.  If desired, set up the Tank Capacity Mode as described in the Tank Capacity 

Mode section. This will allow you to know at any time the percent of refrigerant 
remaining in the refrigerant cylinder. 

3.  Carefully set the refrigerant cylinder on the weighing platform. 
4.  Attach the cylinder to the charging manifold via a utility hose.  Open the cylinder 

valve and purge air from the hose. 

5.  Program the desired refrigerant charge weight as described in the Programming 

section. Activate the program by pressing the “RUN/STOP” key. 

6.  Open the manifold valve(s). 
7.  The display will indicate the weight charged as negative, indicating refrigerant is 

being removed from the charging cylinder. 

8.  If the refrigerant cylinder empties while charging: 

 

Close all valves. 

 

Press the “HOLD” key to “freeze” the display (as described in the Hold 
Mode Section). 

 

Replace the empty refrigerant cylinder with a full one. Attach and purge hoses. 

 

Press the “HOLD” key to exit the Hold Mode. 

 

Open manifold valve(s). Charging will continue from where it left off. 

9. 

When charging is complete, the alarm will sound. Close all valves and press any 
key to cancel the alarm. 

Summary of Contents for 68860

Page 1: ...Economy Charging Scale...

Page 2: ...he platform The battery level indicator shows the relative strength of the batteries Full power is indicated by four bars As the batteries are depleted the number of bars displayed decreases until no...

Page 3: ...hown on the display This Hold Mode may be used as follows 1 Allow load to settle until display is steady 2 Press the HOLD key The HOLD indicator will turn on and the current weight is now locked on th...

Page 4: ...OFF will show on the display This indicates that the Tank Capacity Mode is currently off 2 Turn the Tank Capacity Mode on by pressing the UP key The display will show ON and the Alternate Numeric Disp...

Page 5: ...residential A C refrigerant charging and recovery Its high resolution also allows accurate critical charging of small refrigeration systems such as commercial freezers To use the 68860 for refrigerant...

Page 6: ...left of the display will turn off to indicate that the sound has been muted Repeat steps 1 and 2 to turn the sound back on NOTE The Mute function only affects the power on and key press beeps It has n...

Page 7: ...s Indicators E Sound Mute Indicator F Floating Negative Indicator indicates weight removed from platform G Battery Level Indicator H Fast Adjustment Indicator I Set Mode Indicator J Tank Capacity Mode...

Page 8: ...ing If the product is found to be defective Ritchie Engineering will repair or replace at our dis cretion Over the counter exchanges will not be authorized Press for power on press hold for power off...

Reviews: