APPENDICES
3.9
Spare Parts List
PART NUMBER
DESCRIPTION
68948
Optional internal rechargeable battery kit with battery and 110V charger
68949
Optional 110/220V power adapter
68950
Thermal printer paper
– 1 roll
68977
In line identifier replacement filter
68978
R-12 replacement hose
68979
R-134a replacement hose
68994
Replacement flow restrictor hose (3 pak)
3.10
Appendix B - Specifications
SAMPLE PARAMETERS:
Vapor or Liquid, oil-free, 500 psig Maximum
CONTAMINATE SENSITIVITY:
Contaminate sensitivity filter is enabled by default. Contact
factory to disable.
IDENTIFIED REFRIGERANTS:
R12, R1234yf, R408A, R409A, R417A*, R421A*, R421B,
R422A, R422B, R422C, R427A, HC (Hydrocarbons)
* Due to similar formulas, R417A and R421A may be identified
as either R417A or R421A
IDENTIFIED & ANALYZED
REFRIGERANTS:
R22,
R32,
R134a,
R404A,
R407C,
R410A,
HC
.
(Hydrocarbons)
SENSOR TECHNOLOGY:
Non-Dispersive Infrared (NDIR)
REFRIGERANT SAMPLE SIZE:
0.3 ounces (8.5 grams) per sample
POWER:
Power Supply:
Input: 90-264VAC, 50-60HZ
Output: 12 VDC, 2.0 AMP
Built in Lithium Iron Phosphate Battery:
LiFE 2100mAh
ENVIRONMENTAL CONDITIONS
Do not expose unit or external components to rain or moisture.
Humidity: 0 to 95% RH non-condensing.
Protect Unit from physical abuse by keeping the unit in the
storage case when not in use.
OPERATIONAL TEMPERATURE:
50-120
o
F (10-49
o
C)
24
Summary of Contents for 68940
Page 1: ...HVAC R REFRIGERANT ANALYZER OPERATION MANUAL Analyzer Part Number 68940...
Page 2: ......