background image

                                                             

ESCO Equipment Supply Company

 

 

15270 Flight Path Drive, Brooksville Fl, 34604  Phone (352) 754-1117 Toll Free (800) 352-9852 Fax (352) 754-4508
 

www.esco.net 

 

wheels balanced with the operation rod in intermediate position. 

(9) Don’t place the equipment upside down when using. 

(10) Please keep the equipment cleaned & out of the reach of children when not using. 

(11) It is natural & normal to appear a little bit of oil leaking when transporting, loading and using it in the 

first time. 

4. Transport: 

The equipment should be packed in carton. Please see the carrying position as below picture:. 

 

CARRYING POSITION

CARRYING POSITION

 

 

5. Equipment Installation, Disassembly and Test. 

(1) Equipment installation, when Disassemble, please see (picture A/B/C/D/E/F). 

(2) Equipment Test: 

a.

 

When the Equipment is off load within rated air pressure scope, operate the handle of hand 

valve clockwise to make the Jack move up to the rated hoisting height. After reach the rated 

hoisting height, boosting system stops working automatically 

(The MAX. air pressure of safety 

valve is 130psi). Operate the handle of hand valve anticlockwise to make the jack move down. 

Dust band and sealing of cylinder work in good order without gas leaking.. 

b.

 

Test the equipment with heavy load by special testing machine. It is able to reach the rated jacking 

capacity and hoisting height within the rated air pressure scope. Dustband and sealing of cylinder 

work in good order without gas leaking. (The MAX. air pressure of safety valve is 130psi)

 

6. Operation and Maintenance. 

(1) Operation of air-operated hydraulic pressure jack. 

a.

 

Operate the handle of hand valve clockwise to carry out lifting. When the equipment lifting 

to the rated height then it will stop lifting automatically by itself with the limitation system. 

b.

 

Operate the handle of hand valve anticlockwise to carry out moving down. The equipment 

will move down automatically by itself with reasonable design principle of air structure. 

(2) Equipment maintenance and troubleshooting. 

1) Equipment maintenance. 

a. Add a few drops of lubricating oil regularly on the air inlet every 30 days once. 

b. Don’t keep it at the acid, alkali and corrosive working place. 

d. Check the oil tank to make sure whether there is enough hydraulic oil or not every 30 days 

once. 

c. Keep it clean daily after using. 

 

Notice: 

1.

 

Carry the equipment with hands in the (carrying 

position), see picture in left side. 

 

2.

 

Please operate it according to the relative warning 

indication which sticks on carton. 

 

3.

 

The operator can move the equipment to any 

places with the help of operation rod and wheels. 

 

 

 

Summary of Contents for 10771

Page 1: ...pany 15270 Flight Path Drive Brooksville Fl 34604 Phone 352 754 1117 Toll Free 800 352 9852 Fax 352 754 4508 www esco net Air Operated Hydraulic Pressure Jack 10771 OPERATION INSTRUCTION Parts Manual Minimum 5 50 Maximum 11 90 ...

Page 2: ...tors according to their different outer size Pull the locked operation rod to carry out 3 different directions lever direction of operation rod host direction of 45 degrees and 90 degrees As for operation procedure please see the label of Air operated hydraulic pressure Jack installation instruction which sticks on the operation rod 2 Make reasonable choice of clean and dry air pressure Grease fil...

Page 3: ... gas leaking b Test the equipment with heavy load by special testing machine It is able to reach the rated jacking capacity and hoisting height within the rated air pressure scope Dustband and sealing of cylinder work in good order without gas leaking The MAX air pressure of safety valve is 130psi 6 Operation and Maintenance 1 Operation of air operated hydraulic pressure jack a Operate the handle ...

Page 4: ...s broken 3 Inside wall of cylinder is broken 1 Starting the equipment under the condition of turnover is strictly prohibited If it is not in this condition check and make sure whether there is enough oil in oil tank or not if not it should add more 2 Check and replace spare parts 3 Check and repair cylinder Booster pump does not work 1 One way valve or spring is broken see picture B 2 Booster pist...

Page 5: ... rod 2 Use the Air operated hydraulic pressure jack on a flat and resistant surface away from drains and holes It is not allowed to use it on a slope floor to avoid lifting objects moving or slipping especially those vehicle Make sure to place some supports under the wheel to avoid slip then the equipment can be moved up or down Please carefully read the label of Warnings which sticks to the opera...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Reviews: