Page 15 of 47
25.12.2018
DIS-14-ek
Rev Nr: 2
3.0 Operation
3.1 Before Commissioning the Dispenser
Learn how to shut down the power supply to the dispenser and pump in case of an emergency.
Test break-away coupling by pulling its both ends.
Regularly check hose, nozzle and break-away coupling.
Regularly check dispenser casing and hydraulic section against damages and leakage.
3.2 Programming the ATC System
For the dispensers equipped with Automatic Temperature Compensation - ATC System, the LPG
compound should be defined into the ATC System. Default from factory, this compound is preset to 30%
butane and 70% propane.
For accurate measurements, it important to set ATC in accordance with the LPG
compound.
Neglect this respon
sibility may result in inaccurate readings and it is beyond Yenen’s
control.
4.0 Rules to consider during transportation and shipping
Dispenser should not be removed from its packing during transportation and storage packaging.
Dispenser must be transported by paying attention to the directional arrows on the meter box
during the transportation.
Do not place heavy objects on the dispenser package.
Dispenser should be protected from water and moisture during transportation.
Dispenser should be moved slowly and carefully. Otherwise CPU and displays may be damaged.