background image

 

 

 
 

Device

 

on

 

/

 

off

 

buttonnia

 

 

 
 

Current

 

temperature

 

inside

 

the

 

chamber

 

 

The

 

voltage

 

at

 

the

 

current

 

reaching

 

the

 

device

 

Battery

 

charge

 

indicator

 

Temperature

 

scale

 

change

 

button

 

!$%!&

 

Settings

 

change

 

button

 

 
 

Slider

 

for

 

changing

 

the

 

target

 

temperature

 

inside

 

the

 

chamber

 

 

 

 

Cooling

 

mode

 

change

 

buttons

 

(MAX

 

/

 

ECO)

 

 

Control

 

panel

 

lock

 

button

 

on

 

the

 

device

 

 

Battery

 

protection

 

mode

 

change

 

buttons

 

(H

 

/

 

M

 

/

 

L)

 

 

 

 

 

 

 

 

 

 

 
 

Setting

 

the

 

minimum

 

temperature

 

 

Setting

 

the

 

maximum

 

temperature

 

 

Setting

 

the

 

compressor

 

start

 

delay

 

after

 

starting

 

the

 

device

 

(

 

in

 

minutes)

 

Chamber

 

hysteresis

 

setting

 

-

 

the

 

compressor

 

will

 

start

 

after

 

exceeding

 

the

 

sum

 

of

 

the

 

set

 

device

 

temperature

 

and

 

hysteresis

 

temperature

 

(example

 

-

 

cooling

 

temperature

 

set

 

on

 

the

 

device:

 

)*+!$,

"

hysteresis

 

temperature:

 

+

 

*!$,

"

compressor

 

restart

 

temperature:

 

)-.!$(

 

Settings

 

enabling

 

leveling

 

of

 

differences

 

between

 

the

 

actual

 

temperature

 

of

 

the

 

interior

 

of

 

the

 

device

 

and

 

the

 

temperature

 

set

 

on

 

the

 

control

 

panel

 

(example

 

-

 

chamber

 

cooling

 

temperature

 

set

 

on

 

the

 

device:

 

+!$,

 

actual

 

temperature

 

inside

 

the

 

chamber:

 

)/!$,

"

the

 

temperature

 

should

 

be

 

set

 

to

 

level

 

the

 

+

 

/!$

"

differences)

 

Setting

 

delaying

 

/

 

accelerating

 

the

 

compressor

 

off

 

after

 

reaching

 

the

 

temperature

 

set

 

on

 

the

 

control

 

panel

 

 

 

Inactive

 

settings

 

for

 

this

 

fridge

 

model

 

 

 

 

 

 

 

 

 

 

Change

 

in

 

application

 

theme

 

 

Changing

 

the

 

application

 

language

 

Restore

 

the

 

default

 

settings

 

of

 

the

 

application

 

Disconnect

 

Bluetooth

 

connection

 

Summary of Contents for BNX42

Page 1: ...PORTABLE FRIDGE WITH COMPRESSOR AND BUILT IN BATTERY USER MANUAL BNX42...

Page 2: ...before cleaning maintenance Power switch should be in position OFF Repairs may only be carried out by qualified persons Self repair can cause serious health or life hazards The device should not be o...

Page 3: ...1 4ft AC DC adapter with 100 240V power cord EU UK User manual 5 Directions for use Before first use remove the device from the packaging clean the inside of the device with a damp cloth and wait 6 ho...

Page 4: ...owered from a 12 24V socket in motor vehicles H high protection M medium protection L low protection Default set to high protection H When connecting the device to the application via Bluetooth Pressi...

Page 5: ...after exceeding the sum of the set device temperature and hysteresis temperature example cooling temperature set on the device hysteresis temperature compressor restart temperature Settings enabling l...

Page 6: ...upply voltage drop Change the protection setting to lower from H high to M medium or from M medium to L low The device displays the F2 code Code informing about fan overload Switch the device off and...

Page 7: ...declares that the BPX42 Portable Refrigerator complies with the European Parliament and Council Directives 2009 125 EC and 2014 53 EU of April 16 2014 on the harmonization of the laws of the Member S...

Page 8: ...N This appliance is intended to be used at an ambient temperature between 3 and 25 od 3 do 6 Airborne acoustical noise emissions dB 38 Trademark YETICOOL Model identifier TX36 TX50 BPX42 BPX52 Categor...

Reviews: