background image

 

 

7.

 

Cleaning

 

and

 

maintenance

 

 

 

 

·

 

Turn

 

off

 

the

 

device

 

and

 

disconnect

 

it

 

from

 

the

 

external

 

power

 

supply

 

before

 

each

 

cleaning

 

Power

 

Switch

 

should

 

be

 

in

 

the

 

position

 

(OFF)

 

·

 

The

 

device

 

must

 

not

 

be

 

cleaned

 

under

 

running

 

water.

 

 

·

 

Do

 

not

 

use

 

aggressive

 

cleaning

 

agents

 

for

 

cleaning.

 

 

·Clean

 

the

 

outside

 

and

 

inside

 

of

 

the

 

device

 

with

 

a

 

damp

 

cloth

 

without

 

using

 

the

 

control

 

panel,

 

power

 

section

 

or

 

ventilation

 

openings.

 

 

8.

 

Troubleshooting

 

the

 

most

 

common

 

faults

 

 

 

 

 

Foodstuffs

 

have

 

been

 

frozen:

 

·

 

Change

 

the

 

cooling

 

temperature

 

to

 

higher,

 

the

 

set

 

temperature

 

is

 

too

 

low.

 

 

The

 

device

 

makes

 

a

 

sound

 

of

 

flowing

 

liquid:

 

·

 

This

 

sound

 

is

 

normal.

 

 

Droplets

 

of

 

liquid

 

appear

 

around

 

the

 

fridge

 

door:

 

·

 

Liquid

 

droplets

 

appear

 

due

 

to

 

the

 

temperature

 

difference

 

between

 

the

 

device

 

and

 

its

 

surroundings,

 

and

 

are

 

normal.

 

 

When

 

starting

 

the

 

device,

 

the

 

compressor

 

makes

 

a

 

loud

 

noise:

 

·

 

It

 

is

 

normal

 

for

 

the

 

compressor

 

to

 

work

 

loudly

 

at

 

start-up

 

 

The

 

device

 

does

 

not

 

work:

 

·

 

Check

 

the

 

power

 

switchis

 

in

 

position

 

 

  

(ON)

 

 

·

 

Check

 

if

 

the

 

device

 

has

 

been

 

switched

 

on

 

with

 

the

 

button

 

.

 

·

 

Check

 

that

 

the

 

device

 

is

 

correctly

 

connected

 

to

 

the

 

power

 

source.

 

·

 

Check

 

whether

 

the

 

power

 

supply

 

is

 

functional.

 

·

 

Check

 

if

 

the

 

fuse

 

has

 

blown.

 

 

The

 

device

 

displays

 

the

 

F1

 

code:

 

·

 

Code

 

informing

 

about

 

12

 

/

 

24V

 

supply

 

voltage

 

drop.

 

Change

 

the

 

protection

 

setting

 

to

 

lower

 

from

 

H

 

(high)

 

to

 

M

 

(medium)

 

or

 

from

 

M

 

(medium)

 

to

 

L

 

(low).

 

 

The

 

device

 

displays

 

the

 

F2

 

code:

 

·

 

Code

 

informing

 

about

 

fan

 

overload.

 

Switch

 

the

 

device

 

off

 

and

 

on

 

again

 

after

 

30

 

minutes.

 

 

The

 

device

 

displays

 

the

 

F3

 

code:

 

·

 

Code

 

informing

 

about

 

activation

 

of

 

protection

 

against

 

too

 

frequent

 

compressor

 

operation.

 

Switch

 

the

 

device

 

off

 

and

 

on

 

again

 

after

 

30

 

minutes.

 

The

 

device

 

displays

 

the

 

F4

 

code:

 

·

 

Code

 

informing

 

about

 

compressor

 

overload.

 

Switch

 

the

 

device

 

off

 

and

 

on

 

again

 

after

 

30

 

minutes.

 

The

 

device

 

displays

 

the

 

F5

 

code:

 

·

 

Code

 

informing

 

about

 

compressor

 

module

 

overheating.

 

Switch

 

the

 

device

 

off

 

and

 

on

 

again

 

after

 

30

 

minutes.

 

 

The

 

device

 

displays

 

the

 

code

 

F6:

 

·

 

Code

 

informing

 

about

 

the

 

inability

 

to

 

read

 

parameters

 

by

 

the

 

device

 

controller.

 

Restart

 

the

 

device.

 

If

 

the

 

problem

 

persists,

 

please

 

contact

 

your

 

dealer.

 

 

The

 

device

 

displays

 

the

 

code

 

F7

 

or

 

F8:

 

·

 

Code

 

informing

 

about

 

temperature

 

sensor

 

error.

 

Please

 

contact

 

the

 

seller.

 

 

9.

 

Battery

 

information

 

 

·

 

The

 

built-in

 

battery

 

undergoes

 

natural

 

degradation

 

during

 

the

 

operation

 

of

 

the

 

device.

 

Expected

 

battery

 

life

 

-

 

up

 

to

 

5000

 

charging

 

cycles.

 

·

 

Battery

 

life

 

is

 

also

 

affected

 

by

 

adverse

 

weather

 

conditions,

 

such

 

as

 

too

 

high

 

or

 

too

 

low

 

ambient

 

temperature,

 

high

 

humidity

 

or

 

exposure

 

to

 

water.

 

·

 

The

 

battery

 

should

 

not

 

be

 

fully

 

discharged.

 

·

 

Charging

 

the

 

built-in

 

battery

 

should

 

only

 

be

 

done

 

with

 

the

 

device

 

with

 

the

 

power

 

switch

 

in

 

the

 

position

 

 

  

(ON)

 

Summary of Contents for BNX42

Page 1: ...PORTABLE FRIDGE WITH COMPRESSOR AND BUILT IN BATTERY USER MANUAL BNX42...

Page 2: ...before cleaning maintenance Power switch should be in position OFF Repairs may only be carried out by qualified persons Self repair can cause serious health or life hazards The device should not be o...

Page 3: ...1 4ft AC DC adapter with 100 240V power cord EU UK User manual 5 Directions for use Before first use remove the device from the packaging clean the inside of the device with a damp cloth and wait 6 ho...

Page 4: ...owered from a 12 24V socket in motor vehicles H high protection M medium protection L low protection Default set to high protection H When connecting the device to the application via Bluetooth Pressi...

Page 5: ...after exceeding the sum of the set device temperature and hysteresis temperature example cooling temperature set on the device hysteresis temperature compressor restart temperature Settings enabling l...

Page 6: ...upply voltage drop Change the protection setting to lower from H high to M medium or from M medium to L low The device displays the F2 code Code informing about fan overload Switch the device off and...

Page 7: ...declares that the BPX42 Portable Refrigerator complies with the European Parliament and Council Directives 2009 125 EC and 2014 53 EU of April 16 2014 on the harmonization of the laws of the Member S...

Page 8: ...N This appliance is intended to be used at an ambient temperature between 3 and 25 od 3 do 6 Airborne acoustical noise emissions dB 38 Trademark YETICOOL Model identifier TX36 TX50 BPX42 BPX52 Categor...

Reviews: