7.C

leaning and maintenance

• Turn off the device and disconnect it from the external power supply before each cleaning.

• The device must not be cleaned under running water.

• Do not use aggressive cleaning agents for cleaning.

• Clean the outside and inside of the device with a damp cloth, bypassing the control panel, power section and ventilation 
openings.

• Manual defrosting
During long-term operation of the device, a layer of frost may appear inside it. This can reduce its performance.
To defrost the device, disconnect it from the power supply, empty the cooling compartment and leave the lid open. After the 
condensation of the frost layer, wipe off the remaining water with a soft cloth or drain excess water through the drain hole at the 
bottom of the cooling chamber. The drain hole is opened by removing its plug. After finishing the maintenance, put the plug back 
in the drain hole. 

8.

 Troubleshooting the most common faults

Foodstuffs have been frozen:
• Change the cooling temperature to higher, the set temperature is too low.

The device makes a sound of flowing liquid:
• This sound is normal.

Droplets of liquid appear around the fridge door:
• Liquid droplets appear due to the temperature difference between the device and its surroundings, and are normal.

When starting the device, the compressor makes a loud noise:
• It is normal for the compressor to work loudly at start-up.

The device does not work:
• Check if the device has been switched on with the button    .
• Check that the device is correctly connected to the power source.
• Check whether the power supply is functional.
• Check if the fuse has blown.
Replacing the fuse 
  1. Remove the fuse cover located in the immediate vicinity of the power socket. 
  2. Remove the fuse and replace it with a new one with the same technical parameters. 
  3. Reinstall the fuse cover.

Fuse specification

The device displays the F1 code:
• Code informing about 12 / 24V supply voltage drop. Change the protection setting to lower from H (high) to M (medium) or from M (medium) to L (low).

The device displays the F2 code:
• Code informing about fan overload. Switch the device off and on again after 30 minutes.

The device displays the F3 code:
• Code informing about activation of protection against too frequent compressor operation. Switch the device off and on again after 30 minutes.

The device displays the F4 code:
• Code informing about compressor overload. Switch the device off and on again after 30 minutes.

The device displays the F5 code:
• Code informing about compressor module overheating. Switch the device off and on again after 30 minutes.

The device displays the code F6:
• Code informing about the inability to read parameters by the device controller. Restart the device. If the problem persists, please contact your dealer.

The device displays the code F7 or F8:
• Code informing about temperature sensor error. Please contact the seller.

Current Rating

Voltage Drop

Cold Resistance

I2t

15 A

102mV

4.8 mΩ

340 A²s