background image

Restoring the default settings of the application

Disconnecting the Bluetooth connection

 Device on/off button

Setting the 

max

 temperature

Setting the m

in

 temperature

Setting the compressor start delay after starting the device (in minutes)

Left ventricular hysteresis setting - the compressor will start after exceeding the sum of the
set device temperature and hysteresis temperature.(example - cooling temperature set
on the device: -20°C, hysteresis temperature: +2°C, compressor restart temperature: -18°C)

Settings enabling leveling of differences between the real temperature of the inside of the left
ventricle of the device and the temperature set on the control panel (example - cooling
temperature of the left ventricle of the device: 0°C, actual temperature inside the ventricle:
-5°C,

 

temperature to be set to level the diffe5°C)

Setting delaying / accelerating the compressor off after reaching the temperature set on the
left ventricle control panel

Right ventricular hysteresis setting - the compressor will start after exceeding the sum of the
set device temperature and hysteresis temperature

(example - cooling temperature set on the

device: -20°C, hysteresis temperature: +2°C, compressor restart temperature: -18°C)

Settings enabling leveling of differences between the actual temperature of the inside of the
right chamber of the device and the temperature set on the control panel (example - cooling
temperature of the right chamber set on the device: 0°C, actual temperature insidethe
chamber: -5°C, temperature to be set to level the diffe5°C)

Setting delaying / accelerating the compressor off after reaching the temperature set on the
right ventricle control panel

6°C

2°C

L-Box  

1°C

R-Box  

2°C

°C

H                             M                            L

MAX                                                     ECO

BACK

SENIOR  SE T TING

Smart  Car  Fridge

Max  Temperature

Min  Temperature

Start  Delay

Le   Hysteresis

Right  Hysteresis

Le   TC:  T≥-6°C

Right  TC:  T≥-6°C

Le   TC:  12≤T˂-6°C

Right  TC:  12≤T˂-6°C

RESET

UNBIND

Le   TC:  T<-12°C

Right  TC:  T<-12°C

Le   TC:  Shutdown

Right  TC:  Shutdown

ON

20°C

-20°C

0M

2°C

2°C

0°C

0°C

0°C

0°C

-4°C

-4°C

0°C

0°C

Current temperature inside the 

left

 chamber 

Current temperature inside the right chamber 

 

Button

 for changing the target temperature inside the 

left

 ventricle

 

Button

 for changing the target temperature inside the 

right

 ventricle

Settings change button

Return to the previous screen

 

Battery protection

 

mode change 

slider

 (H / M / L)

Cooling mode

 

change 

slider

 (MAX / ECO)

Reviews: