background image

YewdaleDefiant

®  

programming instructions  

Part no: 980000

6

Items

Problems

Cause

Solution

1

After connecting power, 

the motor doesn’t work  

or works slowly

1. Connected with the wrong voltage
2. Overloading
3. Incorrect installation leading to 

motor jamming

1. Change to the correct voltage
2. Choose suitable motor torque
3. Check the components

2

After connecting with 

power, only one  

direction works

The limit stop position has not 

opened

Rotate crown 1 or 2 circles by hand on the opposite 

of motor current running direction

3

The motor stops 

suddenly whilst 

running

1. Motor has exceeded overheating 

prot130

o

C

2. Power was cut off
3. Motor arrived at the limited 

position

1. After the motor has cooled sufficiently, motor 

will perform as required

2. The motor will resume once power is back on
3. Check limit stop position by adjusting knob

4

Motor runs in wrong 

direction

Wired incorrectly

Exchange the connection of black and blue wires

Adjusting blind limit stops (motor on left):

NB. The GREY & YELLOW knobs  will be reversed when motor is on the left with 

the fabric standard rolled. See illustrations below:

1

Adjust the GREY 

knob to change  

UP limit stop 

position

2

Adjust the YELLOW 

knob to change  

DOWN limit stop 

position

GREY

YELL OW

GREY

YELL OW

Programming Instructions

YewdaleDefiant

®

 230v AC Tubular Motor (980000)

Trouble Shooting: 