YewdaleDefiant
®
programming instructions
Part no: 980000
6
Items
Problems
Cause
Solution
1
After connecting power,
the motor doesn’t work
or works slowly
1. Connected with the wrong voltage
2. Overloading
3. Incorrect installation leading to
motor jamming
1. Change to the correct voltage
2. Choose suitable motor torque
3. Check the components
2
After connecting with
power, only one
direction works
The limit stop position has not
opened
Rotate crown 1 or 2 circles by hand on the opposite
of motor current running direction
3
The motor stops
suddenly whilst
running
1. Motor has exceeded overheating
prot130
o
C
2. Power was cut off
3. Motor arrived at the limited
position
1. After the motor has cooled sufficiently, motor
will perform as required
2. The motor will resume once power is back on
3. Check limit stop position by adjusting knob
4
Motor runs in wrong
direction
Wired incorrectly
Exchange the connection of black and blue wires
Adjusting blind limit stops (motor on left):
NB. The GREY & YELLOW knobs will be reversed when motor is on the left with
the fabric standard rolled. See illustrations below:
1
.
Adjust the GREY
knob to change
UP limit stop
position
2
.
Adjust the YELLOW
knob to change
DOWN limit stop
position
GREY
YELL OW
GREY
YELL OW
Programming Instructions
YewdaleDefiant
®
230v AC Tubular Motor (980000)
Trouble Shooting: