Note:
LA floor level and HA the up limit are not the temperature control parameter adjustment, change will reduce the
temperature control range.
Back to default setting: press the "Rst" button for 3s and display blink 5 times, all parameters back to default
setting;
Parameter lock: press "V" for 3s and blink, display "OFF", means the parameter were locked by the user, this
method isthe same when display "ON" means the parameter were unlocked by the user.(after parameter locking,
user could check but not change, the function of temperature adjust is valid)
Fault tips:
When the sensor short circuit or detect the environment temperature is higher than the upper temperature limit
of 110 degrees, delink and display HHH and stop the output load; When the sensor works normal and detect the
environment temperature is lower than floor temperature limit of -50 degrees, blink and display LLL and stop the
output load.