background image

                                                         

                            

 

User Manual                                                                                                                     

Yifan Industry Co., Ltd. 

                                                                                     

Page 17 of 41 

     

Tel: +86 592 5222813          Fax:+86 592 6101492 
Email: admin@yifanwireless.com , admin@yi-fan.com.cn 
Website: www.yifanwireless.com 

 

Note

If no Backup DSC exists, please configure the Backup DSC same as Main DSC. 

 

Multi Data Service Center

: IP MODEM can connect with at most five DSC at the same time. 

All the multi DSC can receive the same application data . 

 

 

    If the Data Center Number is 0,there is no DSC working. 

If the Data Center Number is 1, IP MODEM work in Main and Backup DSC method.   

When 

Data Center Number

 is greater than 1, IP MODEM works in Multi Data Service Center 

method 

GPS data transmission DSC is self-governed. Setting details please reference the section 3.5.5. 

AT command: 

AT+SVRCNT=x   

x: Data Service Center number 

   

Note: every AT command is terminated with a enter character.   

 

Main Center Addr+Port:     

 

IP Address and Port of the Main DSC, It

s better to set the port greater than 1024. 

 

 

 

AT command of the Main DSC IP address or domain name: 

      AT+IPAD=xxx 

      xxx: The IP address or domain name. 

AT command of the Main DSC port: 

    AT+PORT=xxx 

    xxx: The port value 

 

Backup Center Addr+Port: 

 

IP address and port of the Backup DSC 

 

AT command of the Backup DSC IP address or domain 

      AT+IPSEC=xxx 

      xxx: The IP address or domain name 

AT command of the Backup DSC port 

    AT+PTSEC=xxx 

    xxx: The port value   

 

Summary of Contents for M240 Series

Page 1: ...ion M240 H 3G HSPA HSUPA WCDMA UMTS Modem M240 EV CDMA2000 EVDO Modem M240 E EDGE Modem M240 G GSM GPRS Modem Yifan Industry Limited Add Room1603 No 79 WuShiPu Road HuLi District XiaMen China Zip Code 361000 Tel 86 592 5222813 Fax 86 592 6101492 http www yifanwireless com Documentation No Product Version Page M240 Series User Manual Product Name Total ...

Page 2: ...ustry Limited Without written permission all commercial use of the files from Yifan are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome ...

Page 3: ...Manual Yifan Industry Co Ltd Page 3 of 41 Tel 86 592 5222813 Fax 86 592 6101492 Email admin yifanwireless com admin yi fan com cn Website www yifanwireless com Files Revised Record Date Version Remark Author ...

Page 4: ...User Manual Yifan Industry Co Ltd Page 4 of 41 Tel 86 592 5222813 Fax 86 592 6101492 Email admin yifanwireless com admin yi fan com cn Website www yifanwireless com ...

Page 5: ...nstallation Introduction 11 2 1 General 11 2 2 Encasement List 11 2 3 Installation and Cable Connection 11 2 4 Power 14 2 5 Indicator Lights Introduction 14 Chapter 3 Configuration 15 3 1 Configuration Connection 15 3 2 Configuration Introduction 15 3 3 Run the configure Tool IP Modem Configure exe 15 3 4 Re power IP MODEM 16 3 5 Configuration 16 3 5 1 Data Service Center Settings 16 3 5 2 IP MODE...

Page 6: ...onsumption could be 1ower than 1mA 12VDC It has compatible digital I O channel ADC input pulse counter and pulse wave output function It has been widely used on M2M fields such as intelligent transportation smart grid industrial automation telemetry finance POS water supply environment protection post weather and so on 1 2 Features and Benefits Design for Industrial Application u High powered indu...

Page 7: ...ement software for remote management u Support several work modes u Convenient configuration and maintenance interface High performance u Support TCP server and support multi TCP client connection optional u Support double data centers one main and another backup u Supply 5 I O channels compatible 2 pulse wave output channels 2 analog inputs and one pulse input counters u Support multi data center...

Page 8: ...Hz GPRS EDGE Class 12 236 8Kbps GSM850 900 33dBm GSM1800 1900 30dBm 106 dBm M240 H WCDMA HSDPA HSUPA IP MODEM UMTS WCDMA HSDPA HSUPA 850 1900 2100MHz 850 900 1900 2100MHz optional GSM850 900 1800 1900MHz GPRS EDGE CLASS 12 HSUPA 5 76Mbps Upload speed HSDPA 7 2Mbps Download speed UMTS 384Kbps DL UL 24dBm 109 dBm M240 EV CDMA2000 1X EVDO IP MODEM CDMA2000 1X EVDO Rev A 800MHz 800 1900MHz optional 45...

Page 9: ... 8V user card interface 15KV ESD protection Power Terminal block interface reverse voltage and overvoltage protection Power Input Item Content Standard Power DC 12V 0 5A Power Range DC 5 35V Power Consumption Working States Power Consumption Communication 50 90mA 12VDC 115 165mA 5VDC Standby 25mA 12VDC 45mA 5VDC Sleep 8mA 12VDC 18mA 5VDC Timing Power Off 0 6mA 12VDC 1mA 5VDC Physical Characteristi...

Page 10: ... Ltd Page 10 of 41 Tel 86 592 5222813 Fax 86 592 6101492 Email admin yifanwireless com admin yi fan com cn Website www yifanwireless com Operating Temperature Storage Temperature 40 85ºC 40 185 Operating Humidity 95 Non condensing ...

Page 11: ...General The IP MODEM must be installed correctly to make it work properly Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 Cellular Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 Table 2 1 Encasement List 2 3 Installation and Cable Connection Dimension ...

Page 12: ...k to the SIM UIM card outlet Warning Forbid to install SIM UIM card when powered Installation of antenna Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced User Interface Signal Definition Pin Number Signal Name Default Function Extensible Function 1 PWR Power input a...

Page 13: ...C and pulse output Installation of cable M240 adopts industrial terminal block interface The recommendatory cable is 28 16AWG The detail description of standard layout adapter and communication cables as is following Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarity Black White Alternate Anode Black Cathode RS232 Cable Cable Color Corresponding DB9 M Pin Number Brown Pin 2 Blue Pi...

Page 14: ...cator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator Light State Introduction ON IP MODEM is powered on Power OFF IP MODEM is powered off BLINK Data is communicating ACT OFF No data ON IP MODEM has logged on network Online OFF IP MODEM hasn t logged on network Communication Interface RS232 Communication Interface RS485 M240 Terminal Block Interface User...

Page 15: ...serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure state The steps how to make IP MODEM enter configure state please refer to appendix The following describes how to configure IP MODEM with the configure software tool At the same time it gives out the corresponding AT command of each configuration item 3 3 Run the configure Tool IP M...

Page 16: ...tate At the same time the software will load current settings from IP MODEM and displays on the right configure columns It s now ready to configure 3 5 Configuration 3 5 1 Data Service Center Settings Settings on this page are the parameters related to Data Service Center DSC Data Center Number IP MODEM support two Data Service Center methods to transmit data Main and Backup IP MODEM always tries ...

Page 17: ...than 1 IP MODEM works in Multi Data Service Center method GPS data transmission DSC is self governed Setting details please reference the section 3 5 5 AT command AT SVRCNT x x Data Service Center number Note every AT command is terminated with a enter character Main Center Addr Port IPAddress and Port of the Main DSC It s better to set the port greater than 1024 AT command of the Main DSC IP addr...

Page 18: ...n name AT Command of the 2 5 DSC port AT PORTn xxx n is 1 4 correspond to port of center 2 5 xxx The port value Example Set IP address of center 3 as 166 111 8 238 and port 5001 the AT command is as following AT IPAD2 166 111 8 238 AT PORT2 5001 Main and Backup Center DNS Server When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When the Da...

Page 19: ...cket with TCP protocol Data transmission with TCP protocol heartbeat packet and application data transmission are in the same TCP connection TRNS IP MODEM work as a common GPRS MODEM It can be used in SMS CSD Dial up applications TTRN Heartbeat packet with UDP protocol Data transmission with TCP protocol TLNT IP MODEM work as a telnet client LONG Heartbeat packet with UDP protocol Data transmissio...

Page 20: ...e IP MODEM online AUTO IP MODEM always keeps online SMSD send a special short message to make IP MODEM online CTRL make IP MODEM online through a phone call to IP MODEM DATA send special serial data to make IP MODEM online MIXD the combination of SMSD CTRL DATA IP MODEM will be online when meet one of these three trigger methods AT Command AT ACTI xxxx xxxx one of the above trigger methods Debug L...

Page 21: ... 8 Databit Even parity 1 Stopbit 8O1 8 Databit Odd parity 1 Stopbit AT Command AT SERMODE xxx xxx one of the above serial mode Communication Baudrate 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 bps 38400 38400 bps 56000 56000 bps 57600 57600 bps 115200 115200 bps AT Command AT IPR xxx xxx one of the above baudrate Auto Bac...

Page 22: ... server work fine it will return back to the main server at once AT Command AT RETMAIN x x 0 or 1 Device ID The identity number of IP MODEM the value should be 8 bytes hex decimal characters AT Command AT IDNT aabbccdd aabbccdd the identity number of IP MODEM SIM Card No The phone number of the SIM card AT Command AT PHON xxxxxxxxxx xxxxxxxxxxx the SIM card phone number Bytes Interval The time int...

Page 23: ...tem is only valid when the WorkMode is TCST It s the self defined heartbeat string It can be empty the maximum length is 70 bytes AT Command AT LINKRGST xxx xxx self defined heartbeat string Connect Retry Times Reconnect Time Interval In normal applications IP MODEM will always try to connect with the center even if the center has problems or closed To reduce these unnecessary wireless data flow y...

Page 24: ... 1 No disable transfer meaning This item is only valid when the WorkMode is PROT If this item is set to 0 IP MODEM will transfer meaning to 0xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the PROT work mode If this item is set to 1 all the transmission is transparent AT Command AT STRAIGHT x x 0 or 1 3 5 3 Other Settings Network APN access...

Page 25: ...Command of Username AT USERNAME xxx xxx username AT Command of Password AT PASSWORD xxx xxx password AT Command of Call Center AT CENT xxx xxx call center phone number of ISP SMS Center Your local SMS center number AT Command AT SMSC xxx xxx your local SMS center number Heartbeat Interval Time interval sent heartbeat packet unit is second AT Command AT POLLTIME xxx xxx heartbeat packet time interv...

Page 26: ...e is SMSD or MIXD IP MODEM will keeps in idle state until it receives the trigger short message Then it will connect to the center AT Command AT SMSDPSWD xxx xxx SMS content to trigger IP MODEM online Data Trigger Password This item is valid only when the Trigger Type is DATA or MIXD IP MODEM will keeps in idle state until it receives the trigger on data then it will connect to the center It will ...

Page 27: ...than 1 When one of the configured data center lost connection IP MODEM will try to reconnect after the configured reconnect interval AT Command AT MCONTIME xxx xxx reconnect time interval unit is second 3 5 4 Scheduled Power ON OFF Setting u RTC Real Time Clock Time Setting Click to ensure the setting AT Command AT EXCCLK yyyy mm dd HH MM SS W For example If the current time is at 12 30 on Septemb...

Page 28: ...isabled Scheduled Power On Off function is disabled Default O On Set the IP Modem power on time S Shut Down Set the IP Modem power off time Setting type IP use for power on C use for power off T Time Set the action time point H per Hour Set a time point of every hour D per Day Set a time point of every day W per Week Set a time point of every week M per Month Set a time point of every month I Inte...

Page 29: ...mand AT EXCALx D Note There is no blank in this AT command the same as followings 2 On time switch power on AT Command AT EXCALx OT strLongTime holdTime strLongTime Format 2010 08 01 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 12 30 00 and power off at 13 30 00 on August 1st 2010 AT EXCAL5 OT 2010 08 01 12 30 00 3600 3 Power on per hour ...

Page 30: ... Website www yifanwireless com AT Command AT EXCALx OH strTime holdTime strTime Format 00 30 00 holdTime Hold time value Unit Second For example IP Modem power on at the 30th minute in every hour and power off 10 minutes later AT EXCAL1 OH 00 30 00 600 4 Power on per day AT Command AT EXCALx OD strTime holdTime strTime Format 12 30 00 ...

Page 31: ... power off 1 hour later AT EXCAL3 OD 09 00 00 3600 5 Power on per week AT Command AT EXCALx OW week strTime holdTime week 0123456 replace to Sunday Monday Tuesday Wednesday Thursday Friday and Sunday ordinal strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on every Wednesday and Friday and power off 1 hour later AT EXCAL1 OW 35 09 00 00 3600 Th...

Page 32: ...dmin yi fan com cn Website www yifanwireless com AT Command AT EXCALx OM date strTime holdTime date 0 31 strTime Format 12 30 00 holdTime Hold time value Unit Second For example IP Modem power on at 09 00 00 on the 28th every month and power off 1 hour later AT EXCAL3 OM 28 09 00 00 3600 7 Power on with time interval ...

Page 33: ...alue Unit Second For example IP Modem power on interval every 10 minutes and power off 120 seconds later AT EXCAL1 OP 10 120 8 IP Modem online offline with time interval AT Command AT EXCALx OP intervalTime holdTime intervalTime interval time value Unit Minute holdTime Hold time value Unit Second For example IP Modem online interval every 10 minute and offline 120 seconds later AT EXCAL1 OP 10 120...

Page 34: ...age 34 of 41 Tel 86 592 5222813 Fax 86 592 6101492 Email admin yifanwireless com admin yi fan com cn Website www yifanwireless com AT Command AT EXCALx ST strTime 10 Power off per hour AT Command AT EXCALx SH strTime 11 Power off per day ...

Page 35: ...l 86 592 5222813 Fax 86 592 6101492 Email admin yifanwireless com admin yi fan com cn Website www yifanwireless com AT Command AT EXCALx SD strTime 12 Power off at the same time in every week AT Command AT EXCALx SW week strTime 13 Power off per month ...

Page 36: ...admin yi fan com cn Website www yifanwireless com AT Command AT EXCALx SM date strTime 14 Power off with countdown AT Command AT EXCALx SC afterTime afterTime Countdown value Unit Second For example IP Modem power off 600 seconds later AT EXCAL1 SC 60 Note If the aftertime is 0 the IP Modem will power off immediately ...

Page 37: ...n Display Show the software and hardware version Signal Value Display current wireless signal value Factory setting Restore to factory settings Show Config Show current IP MODEM settings Show Baudrate Display the communication baudrate Auto Detect Simple way to determine whether IP MODEM work fine Save Output Save the output info to a file Save Config Save the current settings to a file you can re...

Page 38: ...ings from a previous saved configure file 3 7 Work State Switch This tool can work in two states Config and Communication Config This state is used to configure parameters of IP MODEM Communication This state is used as a common serial communication tool Reboot Device Enter Communication State This function button is used to reboot IP MODEM and make the software switch to Communication state ...

Page 39: ...endix The following steps describe how to make IP MODEM enter configure state with the Windows XP Hyper Terminal 1 Press Start à Programs à Accessories à Communications à Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 ...

Page 40: ...eless com admin yi fan com cn Website www yifanwireless com Data bits 8 Parity None Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key continuously until IP MODEM enter configure state as following ...

Page 41: ...Co Ltd Page 41 of 41 Tel 86 592 5222813 Fax 86 592 6101492 Email admin yifanwireless com admin yi fan com cn Website www yifanwireless com 7 IP MODEM has entered configure state you can configure the parameters through AT command ...

Reviews: