background image

III. Panel Control Description

O

.

V

.

P

C

.

L

.

P

ON

W

A

V

CC

CV

1

2

3

4

5

6

7

8

9

10

11

12

13

14

1. Model

2. Output voltage

3. Output current

4. Output power

5. Current coarse adjusting knob

6. Current fine adjusting knob

7. The output negative terminal

8. Connection wire

9. The output positive terminal

10. Power switch

11.Voltage coarse adjusting knob

12. Voltage fine adjusting knob

13. Constant current indicator

14.Constant voltage indicator

1.   Connecting to the power source, set the machine input voltage to the same 
     with use voltage (AC110V/220V).
2.   Turn on the power switch, indicator C.V light (current coarse and fine 
     adjustment knob does not 0 ), current and voltage display shows the “000” , a 
     voltage display the output voltage.
3.   Adjust the voltage coarse/fine knob to the request voltage ( current coarse and 
     fine adjustment knob not 0), output voltage range: 0-30V DC.
4.   When connecting to an external load to the “+”, “-” output terminals, output “+” 
     or “-” posts must have a reliable connection with GND terminal, it can reduce 
     the output ripple of power.

IV. Usage Instruction 

Operation

1.   Firstly, adjust voltage coarse and fine knob to the voltage value between 2 to 5V 
     (current coarse and fine adjustment knob is not 0).
2.   And then adjust current coarse and fine knob to 0 (Anti-clockwise to the end).
3.   Connect output terminal 

+

 and 

-

 with wire.

4.   Then adjust the current coarse and fine knob to set the working voltage and 
     then you can continue your operation.

Current Setting

This machine is the type that the voltage and current can convert automatically. It 
means that the regulator voltage and current keeps converting according to the 
load change. The switching point between the regulation and the steady current 
state becomes the transition point.

For example:

 When the machine is in stable state, if the output voltage is 

constant, the output current will change according to the load and there is no any 
change for output voltage. When the load increase(resistance decrease) , voltage 
is down. The conversion of regulator voltage and current is shown from panel LED 
indicator, CV indicator for regulator voltage and CC indicator for regulator current.

Voltage/Current Characteristics

3

4

Summary of Contents for 305D IV

Page 1: ...er supply Please read the user guide thoroughly before using and keep it in a safe place for future reference Statement The company reserves the right to improve and upgrade products product specifications and design are subject to change without notice 305D English IV INSTRUCTION MANUAL ...

Page 2: ...ge should be not exceed setting value 4 Do not use the product in environments where temperatures exceed 40 C 5 When charging the battery do not reverse the positive and negative terminals to avoid damage to the battery 6 This product is of a fan less design full power output should be at least 4 hours For longer continuous operation please set the usage control rate under 80 otherwise an artificia...

Page 3: ...erminal it can reduce the output ripple of power IV Usage Instruction Operation 1 Firstly adjust voltage coarse and fine knob to the voltage value between 2 to 5V current coarse and fine adjustment knob is not 0 2 And then adjust current coarse and fine knob to 0 Anti clockwise to the end 3 Connect output terminal and with wire 4 Then adjust the current coarse and fine knob to set the working voltage ...

Page 4: ...y we provide a lifetime warranty service free of labor costs charge only spare parts costs 4 Failure to present warranty card during warranty period the company will not be a free service 5 Users need warranty service please contact your original sales unit 6 When users need warranty service please provide warranty card and purchase invoice or receipt of the certificate of the company seal 7 Warran...

Reviews: