7
The measuring unit of canister gauge is divided into two categories, one is US unit "Y" (1 "Y" is
approximately equal to 1 aunce), and the other is metric unit "ml" (1 "ml" is approximately equal to 1
millilitre).
2) HOW TO READ CANISTER GAUGES
If the bottom of black gauge marks "31.25/48", i.e. "1Y=48cells=31.25ml", then the measurement
method is as follows: the weight at black gauge reticle "28" equals 28*31.25/48.
If the bottom of red gauge marks
"31.25/384", i.e. 31.25/384=1 red cell=0.08ml, then the
measurement method is as follows: the weight of red gauge "1"=8 red cells=8*31.25/384.
If the bottom of black gauge marks "6ml", i.e. "1cells=1ml", then the measurement method is as
follows: 10cells=10ml at black gauge.
If the bottom of red gauge marks "7ml", then the measurement method is as follows: the weight of
red gauge "1"=10 red cells=1 ml, 1 red cell=0.1ml.
Note: When you operate with double pumps double gauges, please use black gauge in even number
for those gauge numbers above "6" and use red gauge in odd number for those gauge numbers
below "6".
3) EVACUATION BEFORE USE
1. Manually stir all kinds of colorants and pour into each canister, and then put on color stickers.
Cover the canisters with lids. Note: For new machines, please must evacuate before pouring
colorants. You don't need to evacuate again for future use. If you do evacuation incorrectly, air might
flow in. For example, if the valve is not closed when you draw the red handle up, air would come in.
You need to re-do evacuation when any air comes in.
2. Unfold the supporting plate, and move up the plate to proper height.
3. Fix the position of canister that you want to evacuate: press the red ball handle on the left of
dispenser case, slightly push the turntable, and then release the hand pressing red ball handle.
Operating rod will lock the position hole and you can see the canister that you want to evacuate is
now right in front of you, in the middle of supporting plate.
4. Put container onto the supporting plate, let the nozzle of canister point to the opening of container.
5. keep pressing inward the black button with your thumb, and draw the black gauge up to "1" Y
position. release the black button. Then the black gauge will automatically lock at "1" Y. Slowly draw
the red handle up to top, and slowly press down. Repeat 6~7 times. After that, hold the black gauge
with right hand, and use left thumb to press inward the black button. Then slowly put down the gauge
on right hand and release the left thumb. Then the black gauge return to "0" position.
6. Keep pressing inward the red button with your thumb, and draw the red gauge up to "6" position.
release the red button. The red gauge will automatically lock at "6". Then slowly draw the red handle
NOTICE
:
if the canisters was filled with colorants or haven’t be used for a long time, the
colorants should be stirred two times a day or need to discharge all the colorants and clean
the canisters and the pums.
Summary of Contents for YJ-2S
Page 16: ...16 Shaker Part ...