5.5- Check the Voltage Supply ;
ATEX conforming gear units are supplied by YILMAZ without motor. The motor that will be
fitted must have ATEX certificate and the instruction manual of the electric motor provider
must be observed. Observe the name plate of the electric motor and the instructions of
the supplier. Use experienced electric technician. The gearbox and the motor must be
grounded to prevent potential differences of earth and gearbox / motor.
Using wrong connection or voltage can damage the electric motor or environment. The
electric connection must be done by experienced electric technician.
The gearbox and the motor must be grounded to prevent potential difference of earth and
gearbox / motor after installation before starting up.
5.6- Check the Mounting Position ;
The mounting position must be in accordance with the mounting position mentioned on the
name plate. If different please contact YILMAZ REDUKTOR for possibilities of using in a
different mounting position then indicated on the name plate without informing YILMAZ
REDUKTOR will cancel the ATEX conformity and YILMAZ does not take any
responsibility.
Do not mix synthetic oils with mineral oils which can cause serious damage on the gear
unit.
5.7- Usage of Breather Plug ;
Breather plugs are supplied as a standard part for ATEX conforming gear units. The
breather plug is attached to the gear unit and must be changed with the most top plug ac-
cording to the mounting position. Take out the plug over the gear box and replace it with
the supplied breather plug after assembling to its place and before start-up.
The breather plugs are opened at 0.2 bar pressure.
After opening the plugs use Locktite when locking them again.
All plug points are not machined. Only plugs according mounting position is machined. If
no mounting position is mentioned by ordering the standard M1 position plugs are
machined.