Malfcode
:
P0201
Information
:
Injector 1 Circuit Malfunction
ITEM
OPERATION
RESULT
NEXT STEP
1
Connect the diagnostic tool, and ignition on.
Next
2
Remove the conneter of injecor 1, use multimeter to check whether the
voltage of Pin A is about 12V.
Yes
Step 4
No
Next
3
Check whether the connection between pin A and the main power relay is
short to gound or open.
Yes
Harness issue
No
Next
4
Use multimeter to measure whether the resistance between pin A and B of
the injecotr is about 10-14
Ω
@ 20
℃
No
Change the injector
Yes
Next
5
Use the multimeter to check whether the voltage of Pin B is about 12V.
Yes
Help
No
Next
6
Check whether the connection between pin B of the injector and J2-05 of
the ECU is open or short to battery/ground.
Yes
Harness issue
No
Help
Malfcode
:
P0230/P0232
Information
:
FPR Coil Circuit Low/High Voltage or Open
ITEM
OPERATION
RESULT
NEXT STEP
1
Connect the diagnostic tool, and ignition off
next
2
Wait about 30s. Remove the fuel pump realy, ignition on. Check whether
voltage of the relay feeder ear is about 12V
Yes
Change the pump
No
Next
3
Check whether the feeder ear is short to ground or open.
Yes
Harness issue
No
Help
Malfcode
:
P0351
Information
:
Cylinder 1 Ignition Coil Malfunction
ITEM
OPERATION
RESULT
NEXT STEP
1
Connect the diagnostic tool, and ignition on.
next
2
Remove the connector and check whether the voltage of pin + is about 12V.
Yes
Step 4
No
Next
3
Check whether the connection of the pin + and main power relay is open or
short to ground.
Yes
Harness issue
No
Next
4
Use multimeter to check wheter the resistance of the two coil pins is
0.5-0.65
Ω
@20
℃
Yes
Change coil
No
Next
5
Use multimeter to check whether the voltage of pin B is about 12V.
Yes
Help
No
Next
6
Check whether the connection of pin 2 of the coil and J2-01 of ECU is open
or shor to battery/ground.
Yes
Harness issue
No
Help
Malfcode
:
P0505
Information
:
Idle Speed Control Error
ITEM
OPERATION
RESULT
NEXT STEP
1
Connect the diagnostic tool, and ignition off
next
2
Remove the connector. Use multimeter to check whether the resistance
between pin A and pin D, pin B and pin C is about 53
±
5.3
Ω
Yes
Next
No
Change stepper
motor
3
Check whether the 4 wires are short to battery/ground or open.
Yes
Harness issue
No
Help
Summary of Contents for YG125-30B
Page 99: ...YG125 30B Maintenance Manual Frame and exhaust system 106 10 Frame and exhaust system...
Page 130: ...YG125 30B Maintenance Manual Illumination signal system 136 Circuit schematic drawing...
Page 141: ...YG125 30B Maintenance Manual Engine management system 147 Circuit schematic drawing...
Page 151: ...YG125 30B Maintenance Manual Electrical System Diagram 157 19 Electrical System Diagram...