precipitation. 

In order to reduce the potential for electrical and thermal shock, Yingli Solar 
recommends cleaning PV modules during early morning or late afternoon hours 
when solar radiation is low and the modules are cooler, especially in regions 
with hotter temperatures. 

Never attempt to clean a PV module with broken glass or other signs of exposed 
wiring, as this presents a shock hazard.

Clean the glass surface of the PV modules with a soft brush using soft, clean 
water (PH6-9) with a recommended pressure less than 690kPa, which is 
typical of most municipal water systems. Water with high mineral content may 
leave deposits on the glass surface and is not recommended.

Yingli Solar PV modules may contain a hydrophobic anti-reflective coating on 
the glass surface to enhance power output and reduce dirt and dust buildup. In 
order to avoid module damage, do not clean PV modules with a power washer 
or pressure washer. Do not use steam or corrosive chemicals to facilitate 
the cleaning of modules. Do not use aggressive tools or abrasive materials 
that could scratch or damage the glass surface. Failure to comply with these 
requirements may adversely affect the PV module performance. 

Yingli Solar PV modules are designed to withstand high snow loads. However, if 
removing snow is desired to enhance production, use a brush to gently remove 
snow. Do not try to remove frozen snow or ice from PV modules. 

D E CO M M I S S I O N I N G

The dismantling of PV systems must be performed with the same care and 
safety precautions used during the initial installation. The PV system can 
generate hazardous voltage even after the system has been disconnected. 
Follow safety regulations for working with live electrical equipment.

R E C YC L I N G

Yingli Solar is a member of PV Cycle, the European association for voluntary 
take back and recycling of PV modules. Please contact PV Cycle at www.
pvcycle.org for details regarding the recycling process.

Meaning of crossed –out wheeled dustbin:   

Do not dispose of electrical appliances as unsorted municipal waste, use 
separate collection facilities.

Contact your local government for information regarding the collection systems 
available.

If electrical appliances are disposed of in landfills or dumps, hazardous 
substances can leak into the groundwater and get into the food chain, damaging 
your health and well-being.

When replacing old appliances with new ones, the retailer is legally obligated to 
take back your old appliance for disposals at least free of charge.

© Yingli Energy (China) Co., Ltd.

InstallationManual_IEC_EN_20200915_V03

YINGLISOLAR.COM

Yingli Energy (China) Co., Ltd. 

service@yingli.com                                     
Service h86-312-8922216    

                                 

Summary of Contents for 1500V 1/2

Page 1: ...n laboratory This Installation and User Manual is available in different languages In cases of discrepancy between versions the English language version shall control Failure to comply with the requir...

Page 2: ...g so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the pa...

Page 3: ...that are approved for use at the maximum short circuit current of the PV module Yingli Solar recommends installers use only sunlight resistant cables qualified for direct current DC wiring in PV syst...

Page 4: ...1703 Flat Plate Photovoltaic Modules and Panels recommends metal combinations not exceed an electrochemical potential difference of 0 5 Volts The frame rails have pre drilled holes marked with a grou...

Page 5: ...s steel bolts nuts and washers The torque of screw tightening should between 14N m to 20N m Figure 11 Detail of a bolt mounting attachment Figure 12 1 Mounting rails must run perpendicularly to the lo...

Page 6: ...ngli Solar PV modules are designed to withstand high snow loads However if removing snow is desired to enhance production use a brush to gently remove snow Do not try to remove frozen snow or ice from...

Page 7: ...YL295P 29b YL345P 35b YL300D 30b 1500V YL360D 36b 1500V YL300P 29b 1500V YL330P 35b 1500V YL300P 29b YL350P 35b YL305D 30b 1500V YL365D 36b 1500V YL305P 29b 1500V YL335P 35b 1500V YL305P 29b YL355P 3...

Page 8: ...1500V YGE 144 Cell half Cell YGE 144 Cell half Cell 1500V YLM 120 Cell half Cell YLM 120 Cell half Cell 1500V YGE 72 Cell Series 2 HSF Smart YGE 120 Cell half Cell YGE 120 Cell half Cell 1500V YLM 72...

Page 9: ...72 Cell Series 2 HSF Smart YLM 144 Cell half Cell also valid for YLM 72 Cell HSF Smart also valid for YGE 144 Cell Half cell YGE 144 cell half cell 1500V YGE 72 Cell Series 2 YLM 72 Cell REAR AND SIDE...

Page 10: ...tion and User Manual page 10 YGE 60 Cell Series 2 Frame Cross Section REAR AND SIDE VIEW DIMENSIONS OF MODULE SERIES WITH 35MM FRAME UNITS mm Legend Legend Grounding holes Mounting holes Drainage hole...

Page 11: ...art YLM 120 Cell half Cell also valid for YLM 60 Cell HSF Smart also valid for YGE 120 Cell Half cell YGE 120 cell half cell 1500V YINGLISOLAR COM Yingli Energy China Co Ltd service yingli com Service...

Reviews: