Yingli Solar offers the YGE-Z Series PV module which features a  

modified aluminum frame that is compatible with mounting and 

grounding hardware manufactured by Zep Solar. Refer to the  

‘YGE-Z Series Installation Supplement’ for installation information. 

Detailed design and installation information of Zep Solar’s mounting 
systems can be found at 

http://www.zepsolar.com/resources.html

.  

The YGE-Z Series PV module warranty will become void if  

non-Zep-certified hardware is attached inside the Zep Groove of 

 

the module frame. 
YGE-Z Series PV modules are also compatible with the mounting  
and grounding methods included in this manual. 

M A I N T E N A N C E

Yingli Solar recommends that PV systems be periodically inspected by 

the installer, or other qualified person. 

The purpose of the PV system inspection is to ensure that all system 
components are functioning properly. At a minimum, this inspection 

should confirm the following:

–  All cables and connector attachments are undamaged  

and properly secured

– No sharp objects are in contact with the PV module surfaces
–  PV modules are not shaded by unwanted obstacles  

and/or foreign material

–  Mounting and grounding components are tightly secured  

with no corrosion

Defects should be addressed immediately. 

 
Cleaning

Over time, dirt and dust can accumulate on the glass surface of the 
module, reducing its power output. Yingli Solar recommends periodic 
cleaning of PV modules to ensure maximum power output, especially in 
regions with low precipitation. 

In order to reduce the potential for electrical and thermal shock, Yingli 

Solar recommends cleaning PV modules during early morning or late 
afternoon hours when solar radiation is low and the modules are cooler, 
especially in regions with hotter temperatures. 
Never attempt to clean a PV module with broken glass or other signs of 
exposed wiring, as this presents a shock hazard.
Clean the glass surface of the PV modules with a soft brush using soft, 

clean water with a recommended pressure less than 100psi (690kPa), 

which is typical of most municipal water systems. Water with high 
mineral content may leave deposits on the glass surface and is not 
recommended.

Yingli Solar PV modules may contain a hydrophobic anti-reflective 

coating on the glass surface to enhance power output and reduce dirt 

and dust buildup. In order to avoid module damage, do not clean PV 

modules with a power washer or pressure washer. Do not use steam or 
corrosive chemicals to facilitate the cleaning of modules. Do not use 
aggressive tools or abrasive materials that could scratch or damage the 
glass surface. Failure to comply with these requirements may adversely 
affect the PV module performance. 
Yingli Solar PV modules are designed to withstand high snow loads. 
However, if removing snow is desired to enhance production, use a brush 
to gently remove snow. Do not try to remove frozen snow or ice from PV 
modules. 

D E C O M M I S S I O N I N G

The dismantling of PV systems must be performed with the same 
care and safety precautions used during the initial installation. The PV 
system can generate hazardous voltage even after the system has been 
disconnected. Follow safety regulations for working with live electrical 
equipment.

Yingli Green Energy Americas, Inc.

info@yingliamericas.com
Tel: +1 (888) 686-8820

© Yingli Green Energy Holding Co. Ltd.

YINGLISOLAR.COM/US  

 

NYSE:

YGE

Installation Manual_UL_EN_201203_v01

Summary of Contents for YGE 245 Series

Page 1: ...rsion shall control Failure to comply with the requirements listed in this manual will invalidate the Limited Warranty for PV Modules as provided by Yingli Solar at the time of sale to the direct customer Additional recommendations are provided to enhance safety practices and performance results Please provide a copy of this manual to the PV system owner for their reference and inform them of all ...

Page 2: ...to any of the surfaces including the frame For your safety do not disassemble or modify Yingli Solar PV modules in any way Doing so may degrade performance or cause irreparable damage and will void any applicable warranties If it is necessary to store PV modules prior to installation the PV modules should remain inside the packaging and protected from exposure that could compromise the durability ...

Page 3: ...nector The module wiring is intended for series connections i e female to male interconnections but can also be used to connect suitable third party electrical devices that may have alternative wiring configurations so long as the manufacturer s instructions are followed Use field wiring with suitable cross sectional areas that are approved for use at the maximum short circuit current of the PV mo...

Page 4: ...Lugs Manufacturer Part Number Material Tightening Torque ILSCO GBL 4DBT Tin plated copper 20 to 25 in lbf 2 3 to 2 6 N m Burndy CL501 TN Tin plated copper 20 25 in lbf 2 3 to 2 6 N m Tyco Electronics SolKlip 1954381 4 Nickel and tin plated copper 15 4 4 1 7 in lbf 1 7 0 5 0 2 N m Table 2 Grounding lug specifications Installation of grounding lugs must be in accordance with the specified instructio...

Page 5: ... 2400 Pa in both the positive and negative directions Figure 11 Detail of a bolt mounting attachment Top down Clamps Third party clamps that have been designed for PV mounting structures are an approved mounting attachment method for Yingli Solar PV modules Modules must be fastened using clamps applied to the top side of the long frame parts A clamp holds two modules except for the clamps at the b...

Page 6: ...lectrical and thermal shock Yingli Solar recommends cleaning PV modules during early morning or late afternoon hours when solar radiation is low and the modules are cooler especially in regions with hotter temperatures Never attempt to clean a PV module with broken glass or other signs of exposed wiring as this presents a shock hazard Clean the glass surface of the PV modules with a soft brush usi...

Page 7: ...ule type Power output Voltage at Pmax Current at Pmax Open circuit voltage Short circuit current Max DC system voltage Max series fuse rating Pmax Vmpp Impp Voc Isc W V A V A V A YGE 295 SERIES YL295P 35b 295 36 3 8 12 45 4 8 63 600 15 YL290P 35b 290 35 8 8 10 45 3 8 62 600 15 YL285P 35b 285 35 5 8 02 45 0 8 50 600 15 YL280P 35b 280 35 5 7 89 45 0 8 35 600 15 YL275P 35b 275 35 5 7 75 45 0 8 30 600...

Page 8: ...3 31 1100 3 94 100 2 17 55 3 94 100 3 94 100 A A A A 38 98 990 37 24 946 1 97 50 22 72 577 16 02 408 77 56 1970 22 72 577 77 56 1970 47 24 1200 3 94 100 Grounding holes 6 ø0 236 6 Mounting holes 6 0 256x0 315 6 5x8 Drainage holes 8 0 12x0 315 3x8 2 17 55 3 94 100 27 44 697 3 94 100 0 47 12 1 26 32 1 97 50 SECTION A A Legend YGE 295 YGE 245 PANDA YGE Z Legend Grounding holes Mounting holes Drainage...

Reviews: