Installation Manual_G/G_IEC_EN_20180715_V02

Never attempts to clean a PV module with broken glass or other signs of 
exposed wiring, as this presents a shock hazard.

Clean the glass surface of the PV modules with a soft brush using soft, clean 
water with a recommended pressure less than 690 kPa, which is typical of most 
municipal water systems. Water with high mineral content may leave deposits 
on the glass surface and is not recommended.

Yingli Solar PV modules may contain a hydrophilic anti-reflective coating on 
the glass surface to enhance power output and reduce dirt and dust buildup. In 
order to avoid module damage, do not clean PV modules with a power washer 
or pressure washer. Do not use steam or corrosive chemicals to facilitate 
the cleaning of modules. Do not use aggressive tools or abrasive materials 
that could scratch or damage the glass surface. Failure to comply with these 
requirements may adversely affect the PV module performance. 

Yingli Solar PV modules are designed to withstand high snow loads. However, if 
removing snow is desired to enhance production, use a brush to gently remove 
snow. Do not try to remove frozen snow or ice from PVmodules. 

D E CO M M I S S I O N I N G

The dismantling of PV systems must be performed with the same care and 
safety precautions used during the initial installation. The PV system can 
generate hazardous voltage even after the system has been disconnected. 
Follow safety regulations for working with live electrical equipment.

Summary of Contents for YGE G/G 60CL/F Series

Page 1: ...trol Failure to comply with the requirements listed in this manual will invalidate the Limited Warranty for PV modules as provided by Yingli Solar at the time of sale to the direct customer Additional...

Page 2: ...e short side of the box including the corresponding part of the upper lid and the bottom lid see Figure 4 Pay attention to not damage the modules during the cutting process Thirdly cut the two inner s...

Page 3: ...party electronic devices connected to PV modules may lead to mismatching and must be installed according to the manufacturer s specified instructions Figure 6 Electrical diagrams of series and parall...

Page 4: ...or optimal performance Yingli Solar recommends that the negative pole of the PV array be connected to ground Equipment Grounding The frame of the PV module as well as any exposed non current carrying...

Page 5: ...in the mechanical mounting instructions of this installation manual The installation shall follow the instructions below If the installation method is different from this manual please contact Yingli...

Page 6: ...taller or other qualified person The purpose of the PV system inspection is to ensure that all system components are functioning properly At a minimum this inspection should confirm the following All...

Page 7: ...e glass surface to enhance power output and reduce dirt and dust buildup In order to avoid module damage do not clean PV modules with a power washer or pressure washer Do not use steam or corrosive ch...

Page 8: ...8 9 18 1500 15 YL270PG2530L F 1 270 30 7 8 80 37 9 9 27 1500 15 YL275PG2530L F 1 275 31 0 8 90 37 9 9 35 1500 15 YL280PG2530L F 1 280 31 2 8 98 38 0 9 43 1500 15 YL285PG2530L F 1 285 31 4 9 08 38 1 9...

Page 9: ...coefficient C 0 05 0 32 0 42 YLM G G 72CL F YL330DG2536L F 2 330 37 1 8 90 45 2 9 46 1500 15 YL335DG2536L F 2 335 37 4 8 96 45 4 9 51 1500 15 YL340DG2536L F 2 340 37 7 9 02 45 6 9 56 1500 15 YL345DG25...

Page 10: ...n and User Manual page 10 CLAMP INSTALLATION DRAWINGS OF PV MODULES UNITS mm YGE G G 60CL YGE G G 72CL YLM G G 60CL YLM G G 72CL 992 1975 360 635 635 350 200 992 1975 360 635 635 350 200 360 953 345 9...

Page 11: ...3 8 Grounding holes 8 6 1981 365 633 633 350 100 998 1981 32 1981 998 Drainage holes 8 3 8 Grounding holes 8 6 365 633 633 350 100 998 1664 32 1664 998 365 949 350 Drainage holes 8 3 8 100 Grounding h...