background image

COMPLETE TUNING INSTRUCTIONS FOR THE FLASHLIGHT

CONTENTS

1. General principles of operating and settings

1-1. Engineering menu
1-2. Configuration and settings of slots (commands)
1-3. Preconfigured user interfaces
1-4.  Changing of preconfigured user interfaces

2. Thermal control settings

2-1. Manual thermal control setting
2-2. Temperature sensor calibration

3. Some particular qualities of Unicorn 1.0

3-1. Battery check and indication
3-2.  Basic features of adjustment
3-3. Smooth adjustment features
3-4. Discrete adjustment features
3-5. Features of the Maximum mode with fast access
3-6. Slots features

1. GENERAL PRINCIPLES OF OPERATING AND SETTINGS

Customization of the Unicorn flashlight operation implies following configuration options:
- bringing to the main menu particular additional options (stroboscope, button lock, 

beacon, button backlight, battery check, tactical mode, additional custom mode); 

connecting the option with particular command («slot»).
- bringing to the main menu particular options of user interface changing (smooth or 

discrete adjustment, memory of modes – on/off, button backlight in the off and on 

state); connecting the option with particular command («slot»).
Commands are configured through the engineering menu. (pt 1-1, 1-2).
Green LED in the button indicates confirmation of the command execution or turning on 

the function; Red LED indicates disabling of the function (for example, memory of modes 

or button backlight).
Engineering menu also allows:
- quickly switch between three pre-configured user interfaces (pt 1-3);
- save the current settings configuration as one of the pre-configured user interfaces (pt 

1-4);
- set up thermal control of the flashlight (pt 2-1, 2-2).

1-1. Engineering menu

To access the engineering menu screw the cap until tight while holding the button.
To exit the engineering menu de energize the flashlight (unscrew the cap).

CAUTION!

 

Before de energizing, make sure that the flashlight is turned off FULLY (button backlight has 

gone out or has switched to the permanent mode). Otherwise, unsaved data will be lost!

Summary of Contents for Unicorn 1.0

Page 1: ...ion with particular command slot bringing to the main menu particular options of user interface changing smooth or discrete adjustment memory of modes on off button backlight in the off and on state c...

Page 2: ...you configure 4 select the option number to be executed by this command with clicking the button corresponding numbers of times Next you can set up other commands in the same way exit the slot setting...

Page 3: ...g the button enable slot setting mode 7 clicks hold the button will flash green execute the 4 clicks command the button will blink green press the button 6 times the number of the battery check option...

Page 4: ...ion as UI 1 enter the engineering menu screw the cap until tight while holding the button execute the command set current configuration as UI 1 13 clicks hold the button will flash green after 1 2 sec...

Page 5: ...50 C Please note that the thermal control is working in the process of the setting so you can not heat the lamp substantially above 50 degrees The set temperature will be used in all UIs but it will b...

Page 6: ...ness of the mode from which they were turned on or 170 lm if turned on from the OFF state When the memory of modes is off the current memorized at the moment brightness mode will be set as the start m...

Page 7: ...Hold starts adjusting the brightness down with switching to basic brightness modes Click and hold turns OFF the flashlight always regardless of the previous mode If Max is activated by a command with...

Reviews: