background image

 

IM CL235

 

5

 

2.4  DC Voltage Measurement 

WARNING 

Do not make measurement on a circuit above 600VDC. This may cause 
shock hazard or damage to the instrument or equipment under test. 

Black test lead

Red test lead

 

(1)  Set the Function Selector switch to the "

V " position. "DC" should be 

shown on the upper left corner of the display. 

(2)  Plug the red test lead into the Hi terminal and the black test lead into Lo 

terminal. 

(3)  Connect the tip of the red and black test leads to the positive (+) and 

negative (-) sides of the circuit under test respectively. Take the reading 
on the display. 

 

2.5  AC Voltage Measurements 

WARNING 

Do not make measurement on a circuit above 600VAC. This may cause 
shock hazard or damage to the instrument or equipment under test. 

Black test lead

Red test lead

 

 

IM CL235

(1)  Set the Function Selector switch to the "

V" position. "AC" should be 

shown on the upper left corner of the display. 

(2)  Plug the red test lead into Hi terminal and the black test lead into the Lo 

terminal. 

(3)  Connect the tip of the red and black test leads to the circuit under test 

and take the reading on the display. 

NOTE 

When the reading of input voltage is 3% of full scale or less in the circuit 
under test or the frequency of voltage is low, symbol "LoHz" is indicated on 
the display. 

 

2.6 Resistance 

Measurement 

WARNING

Never use the instrument on an energized circuit. 

Black test lead

Red test lead

 

(1)  Set the Function Selector switch to the "

" position. The "

" should 

be shown on the upper right corner of the display. 

(2)  Plug the red test lead into the Hi terminal and the black test lead into the 

Lo terminal. Check that "OL" (over indication) is indicated on the LCD 
display. 

(3)  With the tip of the test leads shorted together, press the 

 button to 

offset the resistance of the test leads. 

(4)  Connect the tip of the test leads to the circuit under test and take the 

reading on the display. 

 

 

IM CL235

 

7

 

2.7  Continuity Check (400

 range fixed) 

The continuity check mode is enabled by pressing the 

  button on resis-

tance range. "

" and "

" is indicated on the display to show the instrument 

in the continuity check mode. The buzzer beeps, if the resistance under test is 
20

 or less. 

WARNING 

Never use the instrument on an energized circuit. 

 

(1)  Set the Function Selector switch to the "

" position. 

(2)  Plug the red test lead into the Hi terminal and the black test lead into the 

Lo terminal. Check that "OL" (over indication) is indicated on the LCD 
display. 

(3)  With the tip of the test leads shorted together, press the 

 button to 

offset the resistance of the test leads. 

(4) Press the 

  button once to enter from the normal mode to the conti-

nuity check mode. "

" should be indicated on the display. 

(5)  Connect the tip of the test leads to the circuit under test. If the resistance 

is 20

 or less, the buzzer beeps. 

 

2.8 Frequency 

Measurement 

 On ACA or ACV range, the frequency of the current or voltage under test 

can be counted and shown on the display. 

 In the frequency measurement mode, "

" is indicated on the display. 

 Trigger threshold is 10% of full scale.

 

WARNING 

  Never use the instrument on a high voltage circuit above 600VAC. This 

may cause electrical shock hazard and damage to the instrument or the 
circuit under test. 

  Do not make current measurement with the test leads plugged into the 

instrument. 

 

(1)  Set the Function Selector switch to the "

A" or "

V" position. 

(2) Press the 

  three times to enter from the normal mode to the fre-

quency measurement mode. "

" should be indicated on the display. 

(3)  Follow instructions for ACA or ACV measurement and take the frequency 

reading. 

 

IM CL235

2.9 Peak 

Measurement 

 In the PEAK mode, the display shows current or voltage's crest in effec-

tive value. (For example, when the current or voltage is sinusoidal, the 
reading equals the crest value divided by the square root of two.) The dis-
play reading is constantly updated with a maximum crest. 

 In this mode, "

" is indicated on the display. 

 Response time is 200ms in DC measurement and 500ms in AC meas-

urement. 

WARNING

  Never use the instrument on a circuit above 600V AC/DC. This may cause 

electrical shock hazard and damage to the instrument or the circuit under 
test. 

  Do not make measurement with the test leads plugged into the instrument. 

 

(1)  The PEAK mode is available on DCA, ACA, DCV and DCA ranges. 

Set the Function Selector switch to the "

A", "

A", "

V" or "

V" 

position. 

Note:  Only on DCA range, press the 

  button for about one second to 

zero adjust the reading with the transformer jaws closed. 

(2) Press the 

  button twice to enter from the normal mode to the PEAK 

mode. "

" should be shown on the display. 

(3)  Follow instructions for DCA, ACA, DCV or ACV measurement. 
(4)  For accurate reading, press the 

  button to reset the reading after 

clamping onto the conductor or making test lead connections to the circuit 
under test. Then proceed to measurement. 

AC

DC

Indication this value

Indication this value

 

NOTE 

  In AC measurement, reading are calibrated in RMS values. 

  In DC measurement, the Peak mode is available only for positive reading. 

  In the Peak measurement mode, measuring range is fixed at Hi. 

Summary of Contents for CL235

Page 1: ... Indicates that there is a possibility of serious personal injury of damage to the instrument if the operating procedure is not followed correctly and describes the precautions for avoiding such injury or damage NOTE Draws attention to information essential for understanding the op eration and features ii IM CL235 WARNING Never make measurement on a circuit above 600V AC or 600V DC Do not use the ...

Page 2: ...h to the OFF position after use When the instrument will not be in use for a long period of time Place it in storage after removing the battery Use a damp cloth and detergent for cleaning the instrument Do not use abrasives or solvents NOTE Radiation immunity affects the accuracy of CL235 testers under the condi tions specified in IEC801 3 1993 If equipment generating strong electromagnetic interf...

Page 3: ...t WARNING Do not make measurement on a circuit above 600VDC This may cause shock hazard or damage to the instrument or equipment under test Do not make measurement with the test leads plugged into the instrument Correct Wrong 1 Set the Function Selector switch to the A position DC should be shown on the upper left corner of the display 2 With the transformer jaws closed and without clamping them o...

Page 4: ... LCD display 3 With the tip of the test leads shorted together press the button to offset the resistance of the test leads 4 Press the button once to enter from the normal mode to the conti nuity check mode should be indicated on the display 5 Connect the tip of the test leads to the circuit under test If the resistance is 20Ω or less the buzzer beeps 2 8 Frequency Measurement On ACA or ACV range ...

Page 5: ...witched from the normal 3 times sec to 2 times sec to reduce fluctuation of the reading LoHz is also indicated where input is 3 of full scale or less 3 4 Optional Accessories Clamp Adapter Model 99025 For AC current measurement only Clamp Adapter Model 99025 is designed to increase the measuring capability of a clamp meter With the use of the Clamp Adapter you can not only extend current range ove...

Page 6: ... The scales are however actually calibrated in terms of the effective value of a sine wave though the clamp meter is responding to the average value The calibration is done with a conversion factor of 1 111 for sine wave which is found by dividing the effective value by the average value These instruments are therefore in error if the input voltage or current has some other shape than sine wave Wa...

Page 7: ...r still fails to operate correctly and needs repair con tact the vendor from whom you purchased the instrument or the nearest Yokogawa M C sales office Turn off the POWER switch once then turn it back on again If the tester does not turn on replace the battery with a new one Calibration It is recommended that the instrument be calibrated once every year ...

Page 8: ...IA PTY LTD AUSTRALIA Phone 61 2 9805 0699 Facsimile 61 2 9888 1844 YOKOGAWA BLUE STAR LTD INDIA Phone 91 80 227 1513 Facsimile 91 80 227 4270 LTD YOKOGAWA ELECTRIC RUSSIAN FEDERATION Phone 7 095 737 7868 Facsimile 7 095 737 7869 計 測 機 器 営 業 部 180 8750 東京都武蔵野市中町 2 9 32 電話 0422 52 5984 ファクシミリ 0422 55 8953 関 西 支 店 564 0063 大阪府吹田市江坂町 1 23 101 大同生命江坂ビル 10 階 電話 06 6368 7041 ファクシミリ 06 6368 7045 中 部 支 店 4...

Reviews: