8
IM 701430-51E
11.
Turn the jog shuttle to move the cursor to “Message Format.”
12.
Press the “SELECT” key to select “Std” or “Ext.”
13.
Turn the jog shuttle to move the cursor to Vdiff.
14.
Press the “SELECT” key.
15.
Turn the jog shuttle to select “CAN_H–CAN_L” or “CAN_L–CAN_H” and press
the “SELECT” key.
16.
Turn the jog shuttle to move the cursor to Pattern Format.
17.
Press the “SELECT” key to select “Hex” or “Bin”.
Selecting the Field or Frame Type
18.
Turn the jog shuttle to move the cursor to the field type or frame type to be used
as a trigger condition. Select the type from “Start of Frame,” “Identifier,” “RTR,”
“Data Field,” and “Error Frame.”
19.
Press the “SELECT” key to turn it ON.
When Identifier Is Selected as a Trigger Condition
20.
Turn the jog shuttle to move the cursor to “Condition.”
21.
Press the “SELECT” key the appropriate number of times to select “True” or
“False.”
22.
Turn the jog shuttle to move the cursor to the Identifier (ID1, ID2, ID3, or ID4) on
which to set the bit pattern.
23.
Press the “SELECT” key to turn it ON.
24.
Turn the jog shuttle to move the cursor to the desired bit and press the
“SELECT” key.
25.
If you selected Hex for Pattern Format, turn the jog shuttle to select a value from
“0” to “F” and “X” and press the “SELECT” key. Pressing the “RESET” key will
reset the value to “X.”
If you selected Bin for Pattern Format, press the “SELECT” key the appropriate
number of times to select “0,” “1,” or “X.”
26.
Repeat steps 19 to 22 as many times as necessary.
When Data Field Is Selected as a Trigger Condition
27.
Turn the jog shuttle to move the cursor to “DLC.”
28.
Press the “SELECT” key.
29.
Turn the jog shuttle to set the number of valid bytes. Press the “SELECT” key to
confirm the setting. Pressing the “RESET” key will reset the value to 8.
30.
Turn the jog shuttle to move the cursor to “Condition.”
31.
Press the “SELECT” key.
32.
Turn the jog shuttle to select “True,” “False,” “Greater,” or “Less” and press the
“SELECT” key.
33.
Turn the jog shuttle to move the cursor to the desired bit.
34.
If you selected Hex for Pattern Format, turn the jog shuttle to select a value from
“0” to “F” and “X” and press the “SELECT” key. Pressing the “RESET” key will
reset the value to “X.”
If you selected Bin for Pattern Format, press the “SELECT” key the appropriate
number of times to select “0,” “1,” or “X.”
Note
RTR and Data Field cannot be turned ON simultaneously. If either one is turned ON, the
other is turned OFF.
2. Setting the Trigger Conditions